Wiki source code of BMS LANmodule
Hide last authors
| author | version | line-number | content |
|---|---|---|---|
| |
1.1 | 1 | = General information = |
| 2 | |||
| 3 | [[image:1734099407734-687.png||data-xwiki-image-style-alignment="center" height="167" width="300"]] | ||
| 4 | |||
| |
4.1 | 5 | BMS LANmodule is an extension module that can be inserted to the BMS Mini, BMS Mini S, BMS Main 3, BMS Main X, or BMS Main 3X controller. It allows a BMS controller to be configured over an Ethernet network. |
| |
1.1 | 6 | |
| 7 | (% id="cke_bm_4104S" style="display:none" %) (%%)Overall architecture of a battery system that is controlled by an upper-level system via Ethernet is shown below. | ||
| 8 | |||
| 9 | [[image:1734099501895-554.png||data-xwiki-image-style-alignment="center" height="344" width="450"]] | ||
| 10 | |||
| 11 | = Specifications = | ||
| 12 | |||
| 13 | |**Parameter**|**Value** | ||
| 14 | |Supply voltage, V|5.0 ± 0.5 | ||
| 15 | |Current consumption, mA, max|200 | ||
| 16 | |Network speed, Mbps|10/100 | ||
| 17 | |Dimensions (length × width × height), mm|44 × 42 × 24 | ||
| 18 | |Weight, g|14 ± 2 | ||
| 19 | |(% colspan="2" %)**Operating conditions** | ||
| 20 | |Operating temperature range, ° С|-40 to +85 | ||
| 21 | |Degree of protection from external influences|IP00 | ||
| 22 | |||
| 23 | = Connection procedure = | ||
| 24 | |||
| 25 | (% class="box warningmessage" %) | ||
| 26 | ((( | ||
| 27 | **Attention!** | ||
| 28 | Connecting the BMS LANmodule 1.x is performed to the powered-off BMS controller! | ||
| 29 | ))) | ||
| 30 | |||
| |
5.1 | 31 | The BMS LANmodule must be inserted into the corresponding header of the BMS controller. The device must be fixed to the BMS controller by **11mm M3 standoffs** and M3 screws. |
| |
1.1 | 32 | |
| |
6.1 | 33 | Here is the example of BMS LANmodule header on BMS Main X: |
| |
1.1 | 34 | |
| 35 | [[image:1734099661846-836.png||data-xwiki-image-style-alignment="center" height="423" width="450"]] | ||
| 36 | |||
| 37 | = Configuration = | ||
| 38 | |||
| 39 | |||
| |
5.1 | 40 | Configuration of the BMS LANmodule must be done according to the BMS controller’s configuration manual, see [[Battery management systems>>path:/bin/view/Battery%20management%20systems/]]. Typically, the connection settings are in the “Connectivity -> LAN” section of the settings. |
| |
1.1 | 41 | |
| 42 | (% class="box warningmessage" %) | ||