Wiki source code of BMS LANmodule
Hide last authors
author | version | line-number | content |
---|---|---|---|
![]() |
9.3 | 1 | = Общая информация = |
![]() |
1.1 | 2 | |
3 | [[image:1734099407734-687.png||data-xwiki-image-style-alignment="center" height="167" width="300"]] | ||
4 | |||
![]() |
9.3 | 5 | BMS LANmodule представляет собой модуль расширения, который устанавливается в контроллеры BMS Mini, BMS Mini S, BMS Main X, BMS Main 3 или BMS Main 3X. Он позволяет настраивать BMS через сеть Ethernet. |
![]() |
1.1 | 6 | |
![]() |
9.3 | 7 | Устройство не содержит функций шифрования и криптографии, а также не содержит батареек/аккумуляторов. |
8 | |||
![]() |
1.1 | 9 | (% id="cke_bm_4104S" style="display:none" %) (%%)Overall architecture of a battery system that is controlled by an upper-level system via Ethernet is shown below. |
10 | |||
11 | [[image:1734099501895-554.png||data-xwiki-image-style-alignment="center" height="344" width="450"]] | ||
12 | |||
13 | = Specifications = | ||
14 | |||
![]() |
9.3 | 15 | |**Параметр**|**Значение** |
16 | |Напряжение питания, В|5,0 ± 0,5 | ||
17 | |Потребляемый ток, мА, не более|200 | ||
18 | |Скорость подключения, Мбит/с|10/100 | ||
19 | |Габариты (длина × ширина × высота), мм|44 × 42 × 24 | ||
20 | |Масса, г|14 ± 2 | ||
21 | |(% colspan="2" %)**Условия эксплуатации** | ||
22 | |Диапазон рабочих температур, °С|от -40 до +85 | ||
23 | |Степень защиты от внешних воздействий|IP00 | ||
![]() |
1.1 | 24 | |
25 | = Connection procedure = | ||
26 | |||
27 | (% class="box warningmessage" %) | ||
28 | ((( | ||
29 | **Attention!** | ||
30 | Connecting the BMS LANmodule 1.x is performed to the powered-off BMS controller! | ||
31 | ))) | ||
32 | |||
![]() |
5.1 | 33 | The BMS LANmodule must be inserted into the corresponding header of the BMS controller. The device must be fixed to the BMS controller by **11mm M3 standoffs** and M3 screws. |
![]() |
1.1 | 34 | |
![]() |
7.1 | 35 | Here is the example of header for additional devices on BMS Main X: |
![]() |
1.1 | 36 | |
37 | [[image:1734099661846-836.png||data-xwiki-image-style-alignment="center" height="423" width="450"]] | ||
38 | |||
39 | = Configuration = | ||
40 | |||
41 | |||
![]() |
9.1 | 42 | Configuration of the BMS LANmodule must be done according to the BMS controller’s configuration manual, see [[Battery management systems>>path:/bin/view/Battery%20management%20systems/]]. |
![]() |
1.1 | 43 | |
![]() |
9.1 | 44 | Typically, the connection settings located in the “Connectivity -> LAN” section of the settings. |
45 | |||
![]() |
1.1 | 46 | (% class="box warningmessage" %) |
47 | ((( | ||
48 | To apply new connection settings, it is necessary to restart the BMS controller. | ||
49 | ))) |