Wiki source code of 2. Installation and connection
Last modified by Admin on 2025/03/18 12:35
Hide last authors
author | version | line-number | content |
---|---|---|---|
![]() |
1.1 | 1 | (% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) |
2 | = Installation and connection = | ||
3 | |||
![]() |
8.1 | 4 | == Safety rules == |
5 | |||
6 | Before use, **configure the system**. Proper operation of the device is possible only if it is correctly configured. | ||
7 | |||
8 | (% class="box warningmessage" %) | ||
9 | ((( | ||
10 | To prevent the damage of device avoid electrostatic discharges while working with the device. | ||
11 | ))) | ||
12 | |||
![]() |
1.1 | 13 | == Installation == |
14 | |||
![]() |
4.1 | 15 | Overall and mounting dimensions of BMS Indication are shown on figure below: |
![]() |
1.1 | 16 | |
![]() |
2.1 | 17 | [[image:1734104601122-708.png||data-xwiki-image-style-alignment="center" height="411" width="350"]] |
![]() |
1.1 | 18 | |
19 | |**Parameter**|**Value** | ||
20 | |Overall dimensions (length × width × height), mm|61 × 49 × 27 | ||
21 | |Mounting dimensions (length × width), mm|55 × 43 | ||
22 | |Mounting holes|M3 | ||
23 | |||
24 | == Headers == | ||
25 | |||
![]() |
4.1 | 26 | The BMS Indication has two headers for connecting the BMS (P2 and P3), a header for connecting external equipment (a PC, for example), and a switch which connects a terminal resistor to the CAN bus (SWD1). |
27 | |||
![]() |
1.1 | 28 | === P2, P3 – headers for communication with BMS === |
29 | |||
![]() |
7.1 | 30 | Receptacle Housing: Molex 39012040. Terminals: Molex 5556 |
![]() |
5.1 | 31 | |
![]() |
1.1 | 32 | [[image:1734104743581-727.png||data-xwiki-image-style-alignment="center"]] |
33 | |||
34 | |**Pin**|**Name**|**Description** | ||
35 | |**1**|**CANH**|CAN H line for communication with the BMS controller | ||
36 | |**2**|**CANL**|CAN L line for communication with the BMS controller | ||
37 | |**3**|**+5V**|Supply voltage 5 V | ||
38 | |**4**|**GND**|Ground | ||
39 | |||
40 | === J1 – header for external equipment === | ||
41 | |||
![]() |
3.1 | 42 | [[image:1734104763162-358.png||data-xwiki-image-style-alignment="center" height="66" width="125"]] |
![]() |
1.1 | 43 | |
44 | |**Pin**|**Name**|**Description** | ||
45 | |**1**|-|- | ||
46 | |**2**|**CANL**|CAN L line for communication with external equipment | ||
47 | |**3**|-|- | ||
48 | |**4**|-|- | ||
49 | |**5**|**-**|- | ||
50 | |**6**|**GND**|Ground | ||
51 | |**7**|**CANH**|CAN H line for communication with external equipment | ||
52 | |**8**|**-**|- | ||
53 | |**9**|**-**|- | ||
54 | |||
55 | === SWD1 – CAN terminal resistor switch === | ||
56 | |||
57 | To connect the terminal resistor between the **CANH** and **CANL** lines, switch the SWD1 to the ON position. |