3
4 == Installation ==
5
6 Overall and mounting dimensions of BMS Indication are shown on figure below:
7
8 [[image:1734104601122-708.png||data-xwiki-image-style-alignment="center" height="411" width="350"]]
9
10 |**Parameter**|**Value**
11 |Overall dimensions (length × width × height), mm|61 × 49 × 27
12 |Mounting dimensions (length × width), mm|55 × 43
13 |Mounting holes|M3
14
15 == Headers ==
16
17 The BMS Indication has two headers for connecting the BMS (P2 and P3), a header for connecting external equipment (a PC, for example), and a switch which connects a terminal resistor to the CAN bus (SWD1).
18
19 === P2, P3 – headers for communication with BMS ===
20
21 Receptacle Housing: Molex 39012040. Контакты: Molex 5556
22
23 [[image:1734104743581-727.png||data-xwiki-image-style-alignment="center"]]
24
25 |**Pin**|**Name**|**Description**
26 |**1**|**CANH**|CAN H line for communication with the BMS controller
27 |**2**|**CANL**|CAN L line for communication with the BMS controller
28 |**3**|**+5V**|Supply voltage 5 V
29 |**4**|**GND**|Ground
30
31 === J1 – header for external equipment ===
32
33 [[image:1734104763162-358.png||data-xwiki-image-style-alignment="center" height="66" width="125"]]
34
35 |**Pin**|**Name**|**Description**
36 |**1**|-|-
37 |**2**|**CANL**|CAN L line for communication with external equipment
38 |**3**|-|-
39 |**4**|-|-
40 |**5**|**-**|-
41 |**6**|**GND**|Ground
42 |**7**|**CANH**|CAN H line for communication with external equipment
43 |**8**|**-**|-
44 |**9**|**-**|-
45
46 === SWD1 – CAN terminal resistor switch ===
47
48 To connect the terminal resistor between the **CANH** and **CANL** lines, switch the SWD1 to the ON position.