Wiki source code of 2. Installation and connection
Show last authors
author | version | line-number | content |
---|---|---|---|
1 | (% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) | ||
2 | = Installation and connection = | ||
3 | |||
4 | == Installation == | ||
5 | |||
6 | Overall and mounting dimensions of BMS Indication are shown on figure below: | ||
7 | |||
8 | [[image:1734104601122-708.png||data-xwiki-image-style-alignment="center" height="411" width="350"]] | ||
9 | |||
10 | |**Parameter**|**Value** | ||
11 | |Overall dimensions (length × width × height), mm|61 × 49 × 27 | ||
12 | |Mounting dimensions (length × width), mm|55 × 43 | ||
13 | |Mounting holes|M3 | ||
14 | |||
15 | == Headers == | ||
16 | |||
17 | The BMS Indication has two headers for connecting the BMS (P2 and P3), a header for connecting external equipment (a PC, for example), and a switch which connects a terminal resistor to the CAN bus (SWD1). | ||
18 | |||
19 | === P2, P3 – headers for communication with BMS === | ||
20 | |||
21 | Receptacle Housing: Molex 39012040. Контакты: Molex 5556 | ||
22 | |||
23 | [[image:1734104743581-727.png||data-xwiki-image-style-alignment="center"]] | ||
24 | |||
25 | |**Pin**|**Name**|**Description** | ||
26 | |**1**|**CANH**|CAN H line for communication with the BMS controller | ||
27 | |**2**|**CANL**|CAN L line for communication with the BMS controller | ||
28 | |**3**|**+5V**|Supply voltage 5 V | ||
29 | |**4**|**GND**|Ground | ||
30 | |||
31 | === J1 – header for external equipment === | ||
32 | |||
33 | [[image:1734104763162-358.png||data-xwiki-image-style-alignment="center" height="66" width="125"]] | ||
34 | |||
35 | |**Pin**|**Name**|**Description** | ||
36 | |**1**|-|- | ||
37 | |**2**|**CANL**|CAN L line for communication with external equipment | ||
38 | |**3**|-|- | ||
39 | |**4**|-|- | ||
40 | |**5**|**-**|- | ||
41 | |**6**|**GND**|Ground | ||
42 | |**7**|**CANH**|CAN H line for communication with external equipment | ||
43 | |**8**|**-**|- | ||
44 | |**9**|**-**|- | ||
45 | |||
46 | === SWD1 – CAN terminal resistor switch === | ||
47 | |||
48 | To connect the terminal resistor between the **CANH** and **CANL** lines, switch the SWD1 to the ON position. |