Wiki source code of 2. Installation and connection

Version 3.1 by Admin on 2024/12/13 15:46

Show last authors
1 (% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 = Installation and connection =
3
4 == Installation ==
5
6 The BMS Indication 2.x has two headers for connecting the BMS (P2 and P3), a header for connecting external equipment (a PC, for example), and a switch which connects a terminal resistor to the CAN bus (SWD1).
7
8 [[image:1734104601122-708.png||data-xwiki-image-style-alignment="center" height="411" width="350"]]
9
10 |**Parameter**|**Value**
11 |Overall dimensions (length × width × height), mm|61 × 49 × 27
12 |Mounting dimensions (length × width), mm|55 × 43
13 |Mounting holes|M3
14 |Header types|Molex series Mini-Fit, DB-9F
15
16 == Headers ==
17
18 === P2, P3 – headers for communication with BMS ===
19
20 [[image:1734104743581-727.png||data-xwiki-image-style-alignment="center"]]
21
22 |**Pin**|**Name**|**Description**
23 |**1**|**CANH**|CAN H line for communication with the BMS controller
24 |**2**|**CANL**|CAN L line for communication with the BMS controller
25 |**3**|**+5V**|Supply voltage 5 V
26 |**4**|**GND**|Ground
27
28 === J1 – header for external equipment ===
29
30 [[image:1734104763162-358.png||data-xwiki-image-style-alignment="center" height="66" width="125"]]
31
32 |**Pin**|**Name**|**Description**
33 |**1**|-|-
34 |**2**|**CANL**|CAN L line for communication with external equipment
35 |**3**|-|-
36 |**4**|-|-
37 |**5**|**-**|-
38 |**6**|**GND**|Ground
39 |**7**|**CANH**|CAN H line for communication with external equipment
40 |**8**|**-**|-
41 |**9**|**-**|-
42
43 === SWD1 – CAN terminal resistor switch ===
44
45 To connect the terminal resistor between the **CANH** and **CANL** lines, switch the SWD1 to the ON position.