Last modified by Admin on 2025/03/18 12:35

From version 5.1
edited by Admin
on 2025/02/20 12:43
Change comment: There is no comment for this version
To version 3.2
edited by Admin
on 2024/12/13 16:00
Change comment: Update document after refactoring.

Summary

Details

Page properties
Content
... ... @@ -3,7 +3,7 @@
3 3  
4 4  == Installation ==
5 5  
6 -Overall and mounting dimensions of BMS Indication are shown on figure below:
6 +The BMS Indication 2.x has two headers for connecting the BMS (P2 and P3), a header for connecting external equipment (a PC, for example), and a switch which connects a terminal resistor to the CAN bus (SWD1).
7 7  
8 8  [[image:1734104601122-708.png||data-xwiki-image-style-alignment="center" height="411" width="350"]]
9 9  
... ... @@ -11,15 +11,12 @@
11 11  |Overall dimensions (length × width × height), mm|61 × 49 × 27
12 12  |Mounting dimensions (length × width), mm|55 × 43
13 13  |Mounting holes|M3
14 +|Header types|Molex series Mini-Fit, DB-9F
14 14  
15 15  == Headers ==
16 16  
17 -The BMS Indication has two headers for connecting the BMS (P2 and P3), a header for connecting external equipment (a PC, for example), and a switch which connects a terminal resistor to the CAN bus (SWD1).
18 -
19 19  === P2, P3 – headers for communication with BMS ===
20 20  
21 -Receptacle Housing: Molex 39012040. Контакты: Molex 5556
22 -
23 23  [[image:1734104743581-727.png||data-xwiki-image-style-alignment="center"]]
24 24  
25 25  |**Pin**|**Name**|**Description**