Last modified by Admin on 2025/03/18 12:35

From version 3.2
edited by Admin
on 2024/12/13 16:00
Change comment: Update document after refactoring.
To version 8.1
edited by Admin
on 2025/03/18 12:35
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,9 +1,18 @@
1 1  (% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 2  = Installation and connection =
3 3  
4 +== Safety rules ==
5 +
6 +Before use, **configure the system**. Proper operation of the device is possible only if it is correctly configured.
7 +
8 +(% class="box warningmessage" %)
9 +(((
10 +To prevent the damage of device avoid electrostatic discharges while working with the device.
11 +)))
12 +
4 4  == Installation ==
5 5  
6 -The BMS Indication 2.x has two headers for connecting the BMS (P2 and P3), a header for connecting external equipment (a PC, for example), and a switch which connects a terminal resistor to the CAN bus (SWD1).
15 +Overall and mounting dimensions of BMS Indication are shown on figure below:
7 7  
8 8  [[image:1734104601122-708.png||data-xwiki-image-style-alignment="center" height="411" width="350"]]
9 9  
... ... @@ -11,12 +11,15 @@
11 11  |Overall dimensions (length × width × height), mm|61 × 49 × 27
12 12  |Mounting dimensions (length × width), mm|55 × 43
13 13  |Mounting holes|M3
14 -|Header types|Molex series Mini-Fit, DB-9F
15 15  
16 16  == Headers ==
17 17  
26 +The BMS Indication has two headers for connecting the BMS (P2 and P3), a header for connecting external equipment (a PC, for example), and a switch which connects a terminal resistor to the CAN bus (SWD1).
27 +
18 18  === P2, P3 – headers for communication with BMS ===
19 19  
30 +Receptacle Housing: Molex 39012040. Terminals: Molex 5556
31 +
20 20  [[image:1734104743581-727.png||data-xwiki-image-style-alignment="center"]]
21 21  
22 22  |**Pin**|**Name**|**Description**