1 (% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 = Installation and connection =
3
4 == Safety rules ==
5
6 Before use, **configure the system**. Proper operation of the device is possible only if it is correctly configured.
7
8 (% class="box warningmessage" %)
9 (((
10 To prevent the damage of device avoid electrostatic discharges while working with the device.
11 )))
12
13 == Installation ==
14
15 Overall and mounting dimensions of BMS Indication are shown on figure below:
16
17 [[image:1734104601122-708.png||data-xwiki-image-style-alignment="center" height="411" width="350"]]
18
19 |**Parameter**|**Value**
20 |Overall dimensions (length × width × height), mm|61 × 49 × 27
21 |Mounting dimensions (length × width), mm|55 × 43
22 |Mounting holes|M3
23
24 == Headers ==
25
26 The BMS Indication has two headers for connecting the BMS (P2 and P3), a header for connecting external equipment (a PC, for example), and a switch which connects a terminal resistor to the CAN bus (SWD1).
27
28 === P2, P3 – headers for communication with BMS ===
29
30 Receptacle Housing: Molex 39012040. Terminals: Molex 5556
31
32 [[image:1734104743581-727.png||data-xwiki-image-style-alignment="center"]]
33
34 |**Pin**|**Name**|**Description**
35 |**1**|**CANH**|CAN H line for communication with the BMS controller
36 |**2**|**CANL**|CAN L line for communication with the BMS controller
37 |**3**|**+5V**|Supply voltage 5 V
38 |**4**|**GND**|Ground
39
40 === J1 – header for external equipment ===
41
42 [[image:1734104763162-358.png||data-xwiki-image-style-alignment="center" height="66" width="125"]]
43
44 |**Pin**|**Name**|**Description**
45 |**1**|-|-
46 |**2**|**CANL**|CAN L line for communication with external equipment
47 |**3**|-|-
48 |**4**|-|-
49 |**5**|**-**|-
50 |**6**|**GND**|Ground
51 |**7**|**CANH**|CAN H line for communication with external equipment
52 |**8**|**-**|-
53 |**9**|**-**|-
54
55 === SWD1 – CAN terminal resistor switch ===
56