Installation and connection
Installation
Overall and mounting dimensions of BMS Indication are shown on figure below:
Parameter | Value |
Overall dimensions (length × width × height), mm | 61 × 49 × 27 |
Mounting dimensions (length × width), mm | 55 × 43 |
Mounting holes | M3 |
Headers
The BMS Indication has two headers for connecting the BMS (P2 and P3), a header for connecting external equipment (a PC, for example), and a switch which connects a terminal resistor to the CAN bus (SWD1).
P2, P3 – headers for communication with BMS
Receptacle Housing: Molex 39012040. Terminals: Molex 5556
Pin | Name | Description |
1 | CANH | CAN H line for communication with the BMS controller |
2 | CANL | CAN L line for communication with the BMS controller |
3 | +5V | Supply voltage 5 V |
4 | GND | Ground |
J1 – header for external equipment
Pin | Name | Description |
1 | - | - |
2 | CANL | CAN L line for communication with external equipment |
3 | - | - |
4 | - | - |
5 | - | - |
6 | GND | Ground |
7 | CANH | CAN H line for communication with external equipment |
8 | - | - |
9 | - | - |
SWD1 – CAN terminal resistor switch
To connect the terminal resistor between the CANH and CANL lines, switch the SWD1 to the ON position.