Changes for page 5. Firmware update

Last modified by Admin on 2025/02/28 11:48

From version 6.4
edited by Admin
on 2025/02/28 10:55
Change comment: There is no comment for this version
To version 6.2
edited by Admin
on 2025/02/28 10:54
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -8,7 +8,7 @@
8 8  Required hardware and software:
9 9  
10 10  * PC or laptop with Windows 10 or newer;
11 -* USB-CAN adapter – a device to communicate with the BMS Display;
11 +* BMS USB-CAN – a device to power and communicate with the BMS Display;
12 12  * [[ElectricDeviceMonitor>>https://movicomelectric.com/wa-data/public/site/app/ElectricDeviceMonitorSETUP.exe]] – a software to monitor and configure devices by Movicom Electric;
13 13  * Firmware (*.srec) – a new firmware for the BMS Display.
14 14  
... ... @@ -16,12 +16,14 @@
16 16  
17 17  Follow the steps below:
18 18  
19 -~1. Connect the BMS Display to the USB-CAN adapter. If BMS USB-CAN used, move switches of the to the following positions:
19 +~1. Connect the BMS Display to the USB-CAN adapter.
20 20  
21 +2. If BMS USB-CAN used, move switches of the to the following positions:
22 +
21 21  * 120 Ohm – “I”;
22 22  * +5V – “0”.
23 23  
24 -2. Connect the USB-CAN adapter to a PC.
26 +3. Connect the USB-CAN adapter to a PC.
25 25  
26 26  4. If BMS USB-CAN used, move the switch “+5V” of the BMS USB-CAN to “I”. Otherwise power up the BMS Display. Check that the led of the BMS Display is blinking.
27 27  
... ... @@ -62,4 +62,4 @@
62 62  
63 63  ~11. Return to the “Updater” window and click the “Update” button. The updating process will start.
64 64  
65 -12. Wait the updating process is finished. If using BMS USB-CAN, move the “+5V” switch to the “0” position. Disconnect the BMS Display device from the USB-CAN adapter.
67 +12. Wait the updating process is finished. If using BMS USB-CAN, move the “+5V” switch to the “0” position and disconnect the BMS Displ device from the BMS USB-RS485.