Changes for page 5. Firmware update
Last modified by Admin on 2025/02/28 11:48
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -16,16 +16,16 @@ 16 16 17 17 Follow the steps below: 18 18 19 -~1. Connect the BMS Display to the BMSUSB-CAN.19 +~1. Connect the BMS Display to the USB-CAN adapter. 20 20 21 -2. Move switches of the BMS USB-CANto the following positions:21 +2. If BMS USB-CAN used, move switches of the to the following positions: 22 22 23 23 * 120 Ohm – “I”; 24 24 * +5V – “0”. 25 25 26 -3. Connect the BMSUSB-CAN to a PC.26 +3. Connect the USB-CAN adapter to a PC. 27 27 28 -4. Move the switch “+5V” of the BMS USB-CAN to “I”. Check that the led of the BMS Display is blinking. 28 +4. If BMS USB-CAN used, move the switch “+5V” of the BMS USB-CAN to “I”. Otherwise Check that the led of the BMS Display is blinking. 29 29 30 30 5. Open the Device Manager* and determine a name of an appeared serial port (Click the right mouse button on the Start menu and select the “Device Manager” item): 31 31 ... ... @@ -47,7 +47,7 @@ 47 47 48 48 * In the ElectricDeviceMonitor, select the menu “Tasks – Monitor - BMS Display 1.x”: 49 49 50 -[[image:1740739041707-667.png]] 50 +[[image:1740739041707-667.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="295" width="300"]] 51 51 52 52 * Set the following connection settings and click the “Launch” button: 53 53 ** serial port name of the BMS USB-RS485