Changes for page 5. Firmware update

Last modified by Admin on 2025/02/28 11:48

From version 4.2
edited by Admin
on 2025/02/28 10:37
Change comment: There is no comment for this version
To version 4.5
edited by Admin
on 2025/02/28 10:39
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -16,16 +16,16 @@
16 16  
17 17  Follow the steps below:
18 18  
19 -~1. Connect the BMS Display to the BMS USB-CAN.
19 +~1. Connect the BMS Display to the USB-CAN adapter.
20 20  
21 -2. Move switches of the BMS USB-CAN to the following positions:
21 +2. If BMS USB-CAN used, move switches of the to the following positions:
22 22  
23 23  * 120 Ohm – “I”;
24 24  * +5V – “0”.
25 25  
26 -3. Connect the BMS USB-CAN to a PC.
26 +3. Connect the USB-CAN adapter to a PC.
27 27  
28 -4. Move the switch “+5V” of the BMS USB-CAN to “I”. Check that the led of the BMS Display is blinking.
28 +4. If BMS USB-CAN used, move the switch “+5V” of the BMS USB-CAN to “I”. Otherwise Check that the led of the BMS Display is blinking.
29 29  
30 30  5. Open the Device Manager* and determine a name of an appeared serial port (Click the right mouse button on the Start menu and select the “Device Manager” item):
31 31  
... ... @@ -47,7 +47,7 @@
47 47  
48 48  * In the ElectricDeviceMonitor, select the menu “Tasks – Monitor - BMS Display 1.x”:
49 49  
50 -[[image:1740739041707-667.png]]
50 +[[image:1740739041707-667.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="295" width="300"]]
51 51  
52 52  * Set the following connection settings and click the “Launch” button: