17 17  Follow the steps below:
18 18  
19 -~1. Connect the BMS Display to the BMS USB-CAN.
19 +~1. Connect the BMS Display to the USB-CAN adapter.
20 20  
21 -2. Move switches of the BMS USB-CAN to the following positions:
21 +2. If BMS USB-CAN used, move switches of the to the following positions:
22 22  
23 23  * 120 Ohm – “I”;
24 24  * +5V – “0”.
25 25  
26 -3. Connect the BMS USB-CAN to a PC.
26 +3. Connect the USB-CAN adapter to a PC.
27 27  
28 -4. Move the switch “+5V” of the BMS USB-CAN to “I”. Check that the led of the BMS Display is blinking.
28 +4. If BMS USB-CAN used, move the switch “+5V” of the BMS USB-CAN to “I”. Otherwise power up the BMS Display. Check that the led of the BMS Display is blinking.
29 29  
30 30  5. Open the Device Manager* and determine a name of an appeared serial port (Click the right mouse button on the Start menu and select the “Device Manager” item):
31 31  
... ... @@ -37,7 +37,7 @@
37 37  
38 38  [[image:Battery management systems.BMS Logic 12.4\. Firmware update.WebHome@1733156153290-392.png||data-xwiki-image-style-alignment="center" height="320" width="296"]]
39 39  
40 -8. Select the transport CAN transport (BMS USB-CAN) (1.0.0)” and click the “Settings” button to configure the adapter: select a port name that corresponds to the BMS USB-CAN and 250 kbit/s baud rate.
40 +8. Select the corresponding CAN transport and click the “Settings” button to configure the adapter: select device or port name that corresponds to the USB-CAN adapter and 250 kbit/s baud rate.
41 41  
42 42  [[image:1740738923079-336.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]]
43 43  
... ... @@ -45,25 +45,23 @@
45 45  
46 46  **10. Boot the device to go into the bootloader mode.**
47 47  
48 -**10b.** For the **BMS Logic 12 v3.4 and newer** or **BMS Logic 18 v3.3 and newer** do the following steps:
48 +* In the ElectricDeviceMonitor, select the menu “Tasks – Monitor - BMS Display 1.x”:
49 49  
50 -* In the ElectricDeviceMonitor, select the menu “Tasks – Monitor - BMS Logic 12/18 3.x”:
50 +[[image:1740739041707-667.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="295" width="300"]]
51 51  
52 -[[image:1733156153292-595.png||data-xwiki-image-style-alignment="center" height="320" width="296"]]
53 -
54 54  * Set the following connection settings and click the “Launch” button:
55 -** serial port name of the BMS USB-RS485
56 -** baud rate and data format: 115200 kbps, 8 bits, no parity, 1 stop bit
57 -** address 247
53 +** device or port name that corresponds to the USB-CAN adapter;
54 +** baud rate: 250 kbit/s;
55 +** BMS Display Node ID (20 by default).
58 58  
59 -[[image:1733156153293-550.png||data-xwiki-image-style-alignment="center" height="227" width="410"]]
57 +[[image:1740739961052-896.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="237" width="450"]]
60 60  
61 -* In the opened window, click the “Bootloader button. The device will reboot and will be waiting commands to update the firmware.
59 +* In the opened window, click the “Send” button under "Reset and start bootloader" section. The device will reboot and will be waiting commands to update the firmware.
62 62  
63 -[[image:1733156153294-767.png||data-xwiki-image-style-alignment="center" height="425" width="648"]]
61 +[[image:1740740038720-603.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="553" width="600"]]
64 64  
65 65  * **Select the menu “Monitor - Stop” or click the “Stop” button to release the serial port and allow to use it for updating the firmware.**
66 66  
67 67  ~11. Return to the “Updater” window and click the “Update” button. The updating process will start.
68 68  
69 -12. Wait the updating process is finished. Move the switches “+5V” and “Cells to the “0” position and disconnect the BMS Logic device from the BMS USB-RS485.
67 +12. Wait the updating process is finished. If using BMS USB-CAN, move the “+5V” switch to the “0” position and disconnect the BMS Displ device from the BMS USB-RS485.
1740739041707-667.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +33.2 KB
Content
1740739961052-896.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +12.1 KB
Content
1740740038720-603.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +49.9 KB
Content