Changes for page 5. Firmware update

Last modified by Admin on 2025/02/28 11:48

From version 2.1
edited by Admin
on 2025/02/28 10:35
Change comment: Uploaded new attachment "1740738923079-336.png", version {1}
To version 1.2
edited by Admin
on 2025/02/28 10:31
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -16,28 +16,28 @@
16 16  
17 17  Follow the steps below:
18 18  
19 -~1. Connect the BMS Display to the BMS USB-CAN.
19 +~1. Connect the BMS Display to the BMS USB-CAN with harnesses:
20 20  
21 21  2. Move switches of the BMS USB-CAN to the following positions:
22 22  
23 23  * 120 Ohm – “I”;
24 -* +5V – “0”.
24 +* +5V – “1”.
25 25  
26 -3. Connect the BMS USB-CAN to a PC.
26 +3. Connect the BMS USB-RS485 to a PC.
27 27  
28 -4. Move the switch “+5V” of the BMS USB-CAN to “I”. Check that the led of the BMS Display is blinking.
28 +4. Move the switchesCells” and “+5V” of the BMS USB-RS485 to “I”. Check that the led “DS1” of the BMS Logic 12/18 is blinking.
29 29  
30 30  5. Open the Device Manager* and determine a name of an appeared serial port (Click the right mouse button on the Start menu and select the “Device Manager” item):
31 31  
32 -[[image:Battery management systems.BMS Logic 12.4\. Firmware update.WebHome@1733156153285-215.png||data-xwiki-image-style-alignment="center" height="377" width="382"]]
32 +[[image:1733156153285-215.png||data-xwiki-image-style-alignment="center" height="377" width="382"]]
33 33  
34 34  6. Install and launch the ElectricDeviceMonitor.
35 35  
36 36  7. Click the “Updater” button:
37 37  
38 -[[image:Battery management systems.BMS Logic 12.4\. Firmware update.WebHome@1733156153290-392.png||data-xwiki-image-style-alignment="center" height="320" width="296"]]
38 +[[image:1733156153290-392.png||data-xwiki-image-style-alignment="center" height="320" width="296"]]
39 39  
40 -8. Select the transport “CAN transport (BMS USB-CAN) (1.0.0)” and click the “Settings” button to configure the serial port: select a port name that corresponds to the BMS USB-CAN and 115200 kbps baud rate.
40 +8. Select the transport “Serial port transport (1.0.0)” and click the “Settings” button to configure the serial port: select a port name that corresponds to the BMS USB-RS485 and 115200 kbps baud rate.
41 41  
42 42  [[image:1733156153292-532.png||data-xwiki-image-style-alignment="center" height="318" width="298"]]
43 43  
1740738923079-336.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -6.2 KB