19 19  
20 20  ~1. Connect the BMS IMD to the USB-CAN adapter.
21 21  
22 -2. Move switches of the  to the following positions:
22 +2. If BMS USB-CAN used, move switches of the  to the following positions:
23 23  
24 24  * 120 Ohm – “I”;
25 25  * +5V – “0”.
... ... @@ -26,9 +26,9 @@
26 26  
27 27  3. Connect the USB-CAN adapter to a PC.
28 28  
29 -4. Move the switch “+5V” of the BMS USB-CAN to “I. Check that the led of the BMS IMD is blinking.
29 +4. Power up the BMS IMD device. Check that the led of the BMS IMD is blinking.
30 30  
31 -5. Open the Device Manager* and determine a name of an appeared serial port (Click the right mouse button on the Start menu and select the “Device Manager” item):
31 +5. If BMS USB-CAN used, open the Device Manager and determine a name of an appeared serial port (Click the right mouse button on the Start menu and select the “Device Manager” item):
32 32  
33 33  [[image:Battery management systems.BMS Logic 12.4\. Firmware update.WebHome@1733156153285-215.png||data-xwiki-image-style-alignment="center" height="377" width="382"]]
34 34  
... ... @@ -38,9 +38,9 @@
38 38  
39 39  [[image:Battery management systems.BMS Logic 12.4\. Firmware update.WebHome@1733156153290-392.png||data-xwiki-image-style-alignment="center" height="320" width="296"]]
40 40  
41 -8. Select the "CAN transport (BMS USB-CAN) (1.0.0)" in a drop-down list and click the “Settings” button to configure the adapter:
41 +8. Select the corresponding USB-CAN adapter in a drop-down list and click the “Settings” button to configure the adapter:
42 42  
43 -* select port name that corresponds to the BMS USB-CAN;
43 +* select device or port name that corresponds to the USB-CAN adapter;
44 44  * set 250 kbit/s baud rate.
45 45  
46 46  [[image:1740738923079-336.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]]
... ... @@ -51,10 +51,10 @@
51 51  
52 52  * In the ElectricDeviceMonitor, select the menu “Tasks – Monitor - BMS IMD 1.x”:
53 53  
54 -[[image:1740739041707-667.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="295" width="300"]]
54 +[[image:Battery management systems.BMS Main 3.3\. Configuration.3\.1 General information.WebHome@1735233230234-960.png||alt="I1735233230234-960.png" data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="340" width="450"]]
55 55  
56 56  * Set the following connection settings and click the “Launch” button:
57 -** port name that corresponds to the BMS USB-CAN;
57 +** device or port name that corresponds to the BMS USB-CAN;
58 58  ** baud rate: 250 kbit/s;
59 59  ** BMS IMD Node ID (20 by default).
60 60