Changes for page 5. Firmware update

Last modified by Admin on 2025/02/28 11:48

From version 12.1
edited by Admin
on 2025/02/28 11:25
Change comment: Загрузить новое вложение 1740741924108-471.png
To version 13.3
edited by Admin
on 2025/02/28 11:34
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -3,23 +3,23 @@
3 3  
4 4  == Introduction ==
5 5  
6 -The document describes the steps to update the BMS Display firmware.
6 +The document describes the steps to update the BMS IMD firmware.
7 7  
8 8  Required hardware and software:
9 9  
10 10  * PC or laptop with Windows 10 or newer;
11 -* BMS USB-CAN – a device to power up and communicate with the BMS Display;
12 -** Also Systec, PEAK and Marathon USB-CAN adapters are supported, but external power supply for BMS Display is needed;
11 +* BMS USB-CAN – a device to power up and communicate with the BMS IMD;
12 +** Also Systec, PEAK and Marathon USB-CAN adapters are supported;
13 13  * [[ElectricDeviceMonitor>>https://movicomelectric.com/wa-data/public/site/app/ElectricDeviceMonitorSETUP.exe]] – a software to monitor and configure devices by Movicom Electric;
14 -* Firmware (*.srec) – a new firmware for the BMS Display.
14 +* Firmware (*.srec) – a new firmware for the BMS IMD.
15 15  
16 16  == Updating process ==
17 17  
18 18  Follow the steps below:
19 19  
20 -~1. Connect the BMS Display to the BMS USB-CAN.
20 +~1. Connect the BMS IMD to the USB-CAN adapter.
21 21  
22 -2. Move switches of the BMS USB-CAN to the following positions:
22 +2. If BMS USB-CAN used, move switches of the  to the following positions:
23 23  
24 24  * 120 Ohm – “I”;
25 25  * +5V – “0”.
... ... @@ -26,9 +26,9 @@
26 26  
27 27  3. Connect the USB-CAN adapter to a PC.
28 28  
29 -4. Move the switch “+5V” of the BMS USB-CAN to “I. Check that the led of the BMS Display is blinking.
29 +4. Power up the BMS IMD device. Check that the led of the BMS IMD is blinking.
30 30  
31 -5. Open the Device Manager* and determine a name of an appeared serial port (Click the right mouse button on the Start menu and select the “Device Manager” item):
31 +5. If BMS USB-CAN used, open the Device Manager and determine a name of an appeared serial port (Click the right mouse button on the Start menu and select the “Device Manager” item):
32 32  
33 33  [[image:Battery management systems.BMS Logic 12.4\. Firmware update.WebHome@1733156153285-215.png||data-xwiki-image-style-alignment="center" height="377" width="382"]]
34 34  
... ... @@ -38,7 +38,7 @@
38 38  
39 39  [[image:Battery management systems.BMS Logic 12.4\. Firmware update.WebHome@1733156153290-392.png||data-xwiki-image-style-alignment="center" height="320" width="296"]]
40 40  
41 -8. Select the "CAN transport (BMS USB-CAN) (1.0.0)" in a drop-down list and click the “Settings” button to configure the adapter:
41 +8. Select the сщккуыз in a drop-down list and click the “Settings” button to configure the adapter:
42 42  
43 43  * select port name that corresponds to the BMS USB-CAN;
44 44  * set 250 kbit/s baud rate.
... ... @@ -49,7 +49,7 @@
49 49  
50 50  **10. Boot the device to go into the bootloader mode.**
51 51  
52 -* In the ElectricDeviceMonitor, select the menu “Tasks – Monitor - BMS Display 1.x”:
52 +* In the ElectricDeviceMonitor, select the menu “Tasks – Monitor - BMS IMD 1.x”:
53 53  
54 54  [[image:1740739041707-667.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="295" width="300"]]
55 55  
... ... @@ -56,7 +56,7 @@
56 56  * Set the following connection settings and click the “Launch” button:
57 57  ** port name that corresponds to the BMS USB-CAN;
58 58  ** baud rate: 250 kbit/s;
59 -** BMS Display Node ID (20 by default).
59 +** BMS IMD Node ID (20 by default).
60 60  
61 61  [[image:1740739961052-896.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="237" width="450"]]
62 62  
... ... @@ -68,4 +68,4 @@
68 68  
69 69  ~11. Return to the “Updater” window and click the “Update” button. The updating process will start.
70 70  
71 -12. Wait the updating process is finished. Move the “+5V” switch to the “0” position. and disconnect the BMS Display device from the BMS USB-CAN.
71 +12. Wait the updating process is finished. Move the “+5V” switch to the “0” position. and disconnect the BMS IMD device from the BMS USB-CAN.
1740742073165-496.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +45.3 KB
Content