Changes for page 5. Firmware update

Last modified by Admin on 2025/02/28 11:48

From version 10.1
edited by Admin
on 2025/02/28 11:11
Change comment: There is no comment for this version
To version 11.1
edited by Admin
on 2025/02/28 11:18
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -8,7 +8,7 @@
8 8  Required hardware and software:
9 9  
10 10  * PC or laptop with Windows 10 or newer;
11 -* BMS USB-CAN adapter – a device to power up and communicate with the BMS Display;
11 +* BMS USB-CAN – a device to power up and communicate with the BMS Display;
12 12  ** Also Systec, PEAK and Marathon USB-CAN adapters are supported, but external power supply for BMS Display is needed;
13 13  * [[ElectricDeviceMonitor>>https://movicomelectric.com/wa-data/public/site/app/ElectricDeviceMonitorSETUP.exe]] – a software to monitor and configure devices by Movicom Electric;
14 14  * Firmware (*.srec) – a new firmware for the BMS Display.
... ... @@ -17,7 +17,7 @@
17 17  
18 18  Follow the steps below:
19 19  
20 -~1. Connect the BMS Display to the BMS USB-CAN adapter.
20 +~1. Connect the BMS Display to the BMS USB-CAN.
21 21  
22 22  2. Move switches of the BMS USB-CAN to the following positions:
23 23  
... ... @@ -38,9 +38,9 @@
38 38  
39 39  [[image:Battery management systems.BMS Logic 12.4\. Firmware update.WebHome@1733156153290-392.png||data-xwiki-image-style-alignment="center" height="320" width="296"]]
40 40  
41 -8. Select the CAN transport (BMS USB-CAN) (1.0.0) and click the “Settings” button to configure the adapter:
41 +8. Select the "CAN transport (BMS USB-CAN) (1.0.0)" in a drop-down list and click the “Settings” button to configure the adapter:
42 42  
43 -* select port name that corresponds to the BMS USB-CAN adapter;
43 +* select port name that corresponds to the BMS USB-CAN;
44 44  * set 250 kbit/s baud rate.
45 45  
46 46  [[image:1740738923079-336.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]]
... ... @@ -54,7 +54,7 @@
54 54  [[image:1740739041707-667.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="295" width="300"]]
55 55  
56 56  * Set the following connection settings and click the “Launch” button:
57 -** port name that corresponds to the BMS USB-CAN adapter;
57 +** port name that corresponds to the BMS USB-CAN;
58 58  ** baud rate: 250 kbit/s;
59 59  ** BMS Display Node ID (20 by default).
60 60  
... ... @@ -68,4 +68,4 @@
68 68  
69 69  ~11. Return to the “Updater” window and click the “Update” button. The updating process will start.
70 70  
71 -12. Wait the updating process is finished. Move the “+5V” switch to the “0” position. and disconnect the BMS Display device from the BMS USB-CAN adapter.
71 +12. Wait the updating process is finished. Move the “+5V” switch to the “0” position. and disconnect the BMS Display device from the BMS USB-CAN.