Changes for page 5. Firmware update

Last modified by Admin on 2025/02/28 11:48

From version 1.6
edited by Admin
on 2025/02/28 10:34
Change comment: There is no comment for this version
To version 1.1
edited by Admin
on 2025/02/28 10:29
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -8,36 +8,40 @@
8 8  Required hardware and software:
9 9  
10 10  * PC or laptop with Windows 10 or newer;
11 -* BMS USB-CAN – a device to power and communicate with the BMS Display;
11 +* BMS USB-CAN adapter – a device to power and communicate with the BMS Display;
12 12  * [[ElectricDeviceMonitor>>https://movicomelectric.com/wa-data/public/site/app/ElectricDeviceMonitorSETUP.exe]] – a software to monitor and configure devices by Movicom Electric;
13 -* Firmware (*.srec) – a new firmware for the BMS Display.
13 +* Firmware (*.srec) – a new firmware for the BMS Logic 12/18.
14 14  
15 15  == Updating process ==
16 16  
17 17  Follow the steps below:
18 18  
19 -~1. Connect the BMS Display to the BMS USB-CAN.
19 +~1. Connect the BMS Logic 12 or 18 to the BMS USB-RS485 with harnesses:
20 20  
21 -2. Move switches of the BMS USB-CAN to the following positions:
21 +* X1 header of the BMS Logic device – to the side (“Cells”) header of the BMS USB-RS485;
22 +* X4 header of the BMS Logic device – to the upper header of the BMS USB-RS485.
22 22  
24 +2. Move switches of the BMS USB-RS485 to the following positions:
25 +
23 23  * 120 Ohm – “I”;
27 +* Cells – “0”;
24 24  * +5V – “0”.
25 25  
26 -3. Connect the BMS USB-CAN to a PC.
30 +3. Connect the BMS USB-RS485 to a PC.
27 27  
28 -4. Move the switch “+5V” of the BMS USB-CAN to “I”. Check that the led of the BMS Display is blinking.
32 +4. Move the switchesCells” and “+5V” of the BMS USB-RS485 to “I”. Check that the led “DS1” of the BMS Logic 12/18 is blinking.
29 29  
30 30  5. Open the Device Manager* and determine a name of an appeared serial port (Click the right mouse button on the Start menu and select the “Device Manager” item):
31 31  
32 -[[image:Battery management systems.BMS Logic 12.4\. Firmware update.WebHome@1733156153285-215.png||data-xwiki-image-style-alignment="center" height="377" width="382"]]
36 +[[image:1733156153285-215.png||data-xwiki-image-style-alignment="center" height="377" width="382"]]
33 33  
34 34  6. Install and launch the ElectricDeviceMonitor.
35 35  
36 36  7. Click the “Updater” button:
37 37  
38 -[[image:Battery management systems.BMS Logic 12.4\. Firmware update.WebHome@1733156153290-392.png||data-xwiki-image-style-alignment="center" height="320" width="296"]]
42 +[[image:1733156153290-392.png||data-xwiki-image-style-alignment="center" height="320" width="296"]]
39 39  
40 -8. Select the transport “CAN transport (BMS USB-CAN) (1.0.0)” and click the “Settings” button to configure the serial port: select a port name that corresponds to the BMS USB-CAN and 115200 kbps baud rate.
44 +8. Select the transport “Serial port transport (1.0.0)” and click the “Settings” button to configure the serial port: select a port name that corresponds to the BMS USB-RS485 and 115200 kbps baud rate.
41 41  
42 42  [[image:1733156153292-532.png||data-xwiki-image-style-alignment="center" height="318" width="298"]]
43 43