2 2  = Firmware update =
3 3  
4 4  == Introduction ==
5 5  
6 -The document describes the steps to update the BMS Display firmware.
6 +The document describes the steps to update the BMS IMD firmware.
7 7  
8 8  Required hardware and software:
9 9  
10 10  * PC or laptop with Windows 10 or newer;
11 -* BMS USB-CAN – a device to power and communicate with the BMS Display;
11 +* BMS USB-CAN – a device to power up and communicate with the BMS IMD;
12 +** Also Systec, PEAK and Marathon USB-CAN adapters are supported;
12 12  * [[ElectricDeviceMonitor>>https://movicomelectric.com/wa-data/public/site/app/ElectricDeviceMonitorSETUP.exe]] – a software to monitor and configure devices by Movicom Electric;
13 -* Firmware (*.srec) – a new firmware for the BMS Display.
14 +* Firmware (*.srec) – a new firmware for the BMS IMD.
14 14  
15 15  == Updating process ==
16 16  
17 17  Follow the steps below:
18 18  
19 -~1. Connect the BMS Display to the BMS USB-CAN.
20 +~1. Connect the BMS IMD to the USB-CAN adapter.
20 20  
21 -2. Move switches of the BMS USB-CAN to the following positions:
22 +2. If BMS USB-CAN used, move switches of the  to the following positions:
22 22  
23 23  * 120 Ohm – “I”;
24 24  * +5V – “0”.
25 25  
26 -3. Connect the BMS USB-CAN to a PC.
27 +3. Connect the USB-CAN adapter to a PC.
27 27  
28 -4. Move the switch “+5V” of the BMS USB-CAN to “I. Check that the led of the BMS Display is blinking.
29 +4. Power up the BMS IMD device. Check that the led of the BMS IMD is blinking.
29 29  
30 -5. Open the Device Manager* and determine a name of an appeared serial port (Click the right mouse button on the Start menu and select the “Device Manager” item):
31 +5. If BMS USB-CAN used, open the Device Manager and determine a name of an appeared serial port (Click the right mouse button on the Start menu and select the “Device Manager” item):
31 31  
32 32  [[image:Battery management systems.BMS Logic 12.4\. Firmware update.WebHome@1733156153285-215.png||data-xwiki-image-style-alignment="center" height="377" width="382"]]
33 33  
... ... @@ -35,39 +35,36 @@
35 35  
36 36  7. Click the “Updater” button:
37 37  
38 -[[image:Battery management systems.BMS Logic 12.4\. Firmware update.WebHome@1733156153290-392.png||data-xwiki-image-style-alignment="center" height="320" width="296"]]
39 +[[image:1740743211495-929.png||alt="I1740743211495-929.png" data-xwiki-image-style-alignment="center" height="337" width="450"]]
39 39  
40 -8. Select the transport Serial port transport (1.0.0)” and click the “Settings” button to configure the serial port: select a port name that corresponds to the BMS USB-RS485 and 115200 kbps baud rate.
41 +8. Select the corresponding USB-CAN adapter in a drop-down list and click the “Settings” button to configure the adapter:
41 41  
42 -[[image:1733156153292-532.png||data-xwiki-image-style-alignment="center" height="318" width="298"]]
43 +* select device or port name that corresponds to the USB-CAN adapter;
44 +* set 250 kbit/s baud rate.
43 43  
44 -9. Click the “Browse…” button and open the new firmware file.
46 +[[image:1740738923079-336.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]]
45 45  
48 +9. Click the “Browse…” button and open the new firmware file in .srec format.
49 +
46 46  **10. Boot the device to go into the bootloader mode.**
47 47  
48 -**10a.** For the **BMS Logic 12 v3.3 and older** or **BMS Logic 18 v3.2 and older** (which have an address switch onboard):
52 +* In the ElectricDeviceMonitor, select the menu “Tasks Monitor - BMS IMD 1.x”:
49 49  
50 -* Move all switches to the OFF state so the address is 0. The device will show that it is in the bootloader mode by flashing the DS1 with 0.5Hz frequency.
54 +[[image:Battery management systems.BMS Main 3.3\. Configuration.3\.1 General information.WebHome@1735233230234-960.png||alt="I1735233230234-960.png" data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="340" width="450"]]
51 51  
52 -**10b.** For the **BMS Logic 12 v3.4 and newer** or **BMS Logic 18 v3.3 and newer** do the following steps:
56 +* Select the corresponding USB-CAN apater and set the following connection settings and click the “Launch” button:
57 +** device or port name that corresponds to the USB-CAN adapter;
58 +** baud rate: 250 kbit/s;
59 +** BMS IMD address (22 by default).
53 53  
54 -* In the ElectricDeviceMonitor, select the menu “Tasks – Monitor - BMS Logic 12/18 3.x”:
61 +[[image:1740741924108-471.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="247" width="450"]]
55 55  
56 -[[image:1733156153292-595.png||data-xwiki-image-style-alignment="center" height="320" width="296"]]
63 +* In the opened window, click the “Send” button under "Reset and start bootloader" section. The device will reboot and will be waiting commands to update the firmware.
57 57  
58 -* Set the following connection settings and click the “Launch” button:
59 -** serial port name of the BMS USB-RS485
60 -** baud rate and data format: 115200 kbps, 8 bits, no parity, 1 stop bit
61 -** address – 247
65 +[[image:1740742073165-496.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="397" width="600"]]
62 62  
63 -[[image:1733156153293-550.png||data-xwiki-image-style-alignment="center" height="227" width="410"]]
64 -
65 -* In the opened window, click the “Bootloader” button. The device will reboot and will be waiting commands to update the firmware.
66 -
67 -[[image:1733156153294-767.png||data-xwiki-image-style-alignment="center" height="425" width="648"]]
68 -
69 69  * **Select the menu “Monitor - Stop” or click the “Stop” button to release the serial port and allow to use it for updating the firmware.**
70 70  
71 71  ~11. Return to the “Updater” window and click the “Update” button. The updating process will start.
72 72  
73 -12. Wait the updating process is finished. Move the switches “+5V” and “Cells” to the “0” position and disconnect the BMS Logic device from the BMS USB-RS485.
71 +12. Wait the updating process is finished. Disconnect the BMS IMD device from the USB-CAN adapter.
1740738923079-336.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +6.2 KB
Content
1740739018136-732.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +33.1 KB
Content
1740739041707-667.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +33.2 KB
Content
1740739961052-896.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +12.1 KB
Content
1740740038720-603.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +49.9 KB
Content
1740741924108-471.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +15.7 KB
Content
1740742073165-496.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +45.3 KB
Content
1740743211495-929.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +37.5 KB
Content