... ... @@ -21,40 +21,34 @@
21 21  2. Move switches of the BMS USB-CAN to the following positions:
22 22  
23 23  * 120 Ohm – “I”;
24 -* +5V – “1”.
24 +* +5V – “0”.
25 25  
26 26  3. Connect the BMS USB-CAN to a PC.
27 27  
28 -4. Move the switchesCells” and “+5V” of the BMS USB-RS485 to “I”. Check that the led “DS1” of the BMS Logic 12/18 is blinking.
28 +4. Move the switch “+5V” of the BMS USB-CAN to “I”. Check that the led of the BMS Display is blinking.
29 29  
30 30  5. Open the Device Manager* and determine a name of an appeared serial port (Click the right mouse button on the Start menu and select the “Device Manager” item):
31 31  
32 -[[image:1733156153285-215.png||data-xwiki-image-style-alignment="center" height="377" width="382"]]
32 +[[image:Battery management systems.BMS Logic 12.4\. Firmware update.WebHome@1733156153285-215.png||data-xwiki-image-style-alignment="center" height="377" width="382"]]
33 33  
34 34  6. Install and launch the ElectricDeviceMonitor.
35 35  
36 36  7. Click the “Updater” button:
37 37  
38 -[[image:1733156153290-392.png||data-xwiki-image-style-alignment="center" height="320" width="296"]]
38 +[[image:Battery management systems.BMS Logic 12.4\. Firmware update.WebHome@1733156153290-392.png||data-xwiki-image-style-alignment="center" height="320" width="296"]]
39 39  
40 -8. Select the transport “Serial port transport (1.0.0)” and click the “Settings” button to configure the serial port: select a port name that corresponds to the BMS USB-RS485 and 115200 kbps baud rate.
40 +8. Select the transport “CAN transport (BMS USB-CAN) (1.0.0)” and click the “Settings” button to configure the adapter: select a port name that corresponds to the BMS USB-CAN and 250 kbit/s baud rate.
41 41  
42 -[[image:1733156153292-532.png||data-xwiki-image-style-alignment="center" height="318" width="298"]]
42 +[[image:1740738923079-336.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]]
43 43  
44 -9. Click the “Browse…” button and open the new firmware file.
44 +9. Click the “Browse…” button and open the new firmware file in .srec format.
45 45  
46 46  **10. Boot the device to go into the bootloader mode.**
47 47  
48 -**10a.** For the **BMS Logic 12 v3.3 and older** or **BMS Logic 18 v3.2 and older** (which have an address switch onboard):
48 +* In the ElectricDeviceMonitor, select the menu “Tasks Monitor - BMS Display 1.x”:
49 49  
50 -* Move all switches to the OFF state so the address is 0. The device will show that it is in the bootloader mode by flashing the DS1 with 0.5Hz frequency.
50 +[[image:1740739018136-732.png]]
51 51  
52 -**10b.** For the **BMS Logic 12 v3.4 and newer** or **BMS Logic 18 v3.3 and newer** do the following steps:
53 -
54 -* In the ElectricDeviceMonitor, select the menu “Tasks – Monitor - BMS Logic 12/18 3.x”:
55 -
56 -[[image:1733156153292-595.png||data-xwiki-image-style-alignment="center" height="320" width="296"]]
57 -
58 58  * Set the following connection settings and click the “Launch” button:
59 59  ** serial port name of the BMS USB-RS485
60 60  ** baud rate and data format: 115200 kbps, 8 bits, no parity, 1 stop bit
1740738923079-336.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +6.2 KB
Content
1740739018136-732.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +33.1 KB
Content
1740739041707-667.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +33.2 KB
Content