Changes for page 3. Configuration
Last modified by Admin on 2025/03/03 17:35
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 - Battery managementystems.BMS IMD.WebHome1 +drafts.BMS IMD.WebHome - Content
-
... ... @@ -1,7 +1,7 @@ 1 1 (% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 2 = Configuration = 3 3 4 -The BMS IMD is configured over the CAN bus. The device is a slave in the CANopen network. The ElectricDeviceMonitor software is used for configuring and monitoring device via the USB-CAN adapter. This software supports Systec USB-CANmodul1, PEAK PCAN-USB, Marathon CAN-bus-USB и BMS USB-CAN adapters. 4 +The BMS IMD 1.x is configured over the CAN bus. The device is a slave in the CANopen network. The ElectricDeviceMonitor software is used for configuring and monitoring device via the USB-CAN adapter. This software supports Systec USB-CANmodul1, PEAK PCAN-USB, Marathon CAN-bus-USB и BMS USB-CAN adapters. 5 5 6 6 == Connecting to the device == 7 7 ... ... @@ -36,11 +36,11 @@ 36 36 37 37 == Changing device parameters == 38 38 39 -The BMS IMD parameters are summarized in the "Settings" tab of the "Unified monitor" window. 39 +The BMS IMD 1.x parameters are summarized in the "Settings" tab of the "Unified monitor" window. 40 40 41 41 === Insulation measurement parameters === 42 42 43 -To change the internal parameters of the BMS IMD, select the «IMD» section: 43 +To change the internal parameters of the BMS IMD 1.x, select the «IMD» section: 44 44 45 45 [[image:1734009713290-935.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="350" width="600"]] 46 46 ... ... @@ -47,11 +47,11 @@ 47 47 In this section: 48 48 49 49 * Always allow work – a flag to enable work permanently; 50 -* Control via PDO – a flag that allows to control the device using a PDO message (see [[CANopen protocol>>doc:Batterymanagement systems.BMS IMD.4\.CANopen protocol.WebHome]]);50 +* Control via PDO – a flag that allows to control the device using a PDO message (see the “BMS IMD 1.x – CANopen protocol” document); 51 51 * Alarm resistance, kOhm – resistance value which indicate the resistance fault and triggers discrete output OUT_ERROR, kOhm; 52 52 * Warning resistance, kOhm – resistance value which triggers the low resistance warning, kOhm; 53 -* Transition timeout – a maximum time of the measurement transient process, after which a Timeout error will be generated (see [[Reading device status>>doc:||anchor="HReadingdevicestatus"]]), s. This parameter should be increased if there is significant capacitance between the battery buses and the chassis.54 -* Minimum bus voltage – a battery voltage value below which a Low bus voltage error will be generated (see [[Reading device status>>doc:||anchor="HReadingdevicestatus"]]), V.53 +* Transition timeout – a maximum time of the measurement transient process, after which a Timeout error will be generated (see section 4.3), s. This parameter should be increased if there is significant capacitance between the battery buses and the chassis. 54 +* Minimum bus voltage – a battery voltage value below which a Low bus voltage error will be generated (see section 4.3), V. 55 55 56 56 === Connection parameters === 57 57 ... ... @@ -75,7 +75,7 @@ 75 75 76 76 (% class="box infomessage" %) 77 77 ((( 78 -To apply new settings please restart the BMS IMD device. 78 +To apply new settings please restart the BMS IMD 1.x device. 79 79 ))) 80 80 81 81 == Reading device status == ... ... @@ -122,7 +122,7 @@ 122 122 123 123 == Indication of device work == 124 124 125 -The BMS IMD device has two LED indicators MODE and ERR. 125 +The BMS IMD 1.x device has two LED indicators MODE and ERR. 126 126 127 127 The MODE indicator is green and allows you to determine the operating stage of the device by its blinking frequency: 128 128