Changes for page 3. Configuration
Last modified by Admin on 2025/03/03 17:35
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,17 +1,17 @@ 1 1 (% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 2 = Configuration = 3 3 4 -The BMS IMD 1.xis configured over the CAN bus. The device is a slave in the CANopen network. The ElectricDeviceMonitor software is used for configuring and monitoring device via the USB-CAN adapter. This software supports Systec USB-CANmodul1, PEAK PCAN-USB, Marathon CAN-bus-USB и BMS USB-CAN adapters.4 +The BMS IMD is configured over the CAN bus. The device is a slave in the CANopen network. The ElectricDeviceMonitor software is used for configuring and monitoring device via the USB-CAN adapter. This software supports Systec USB-CANmodul1, PEAK PCAN-USB, Marathon CAN-bus-USB и BMS USB-CAN adapters. 5 5 6 6 == Connecting to the device == 7 7 8 8 To connect to the device, launch ElectricDeviceMonitor, select "Unified monitor" in the main program window. 9 9 10 -[[image:173 4009713280-126.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="435" width="400"]]10 +[[image:Battery management systems.BMS Main 3.3\. Configuration.3\.1 General information.WebHome@1735233230234-960.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="340" width="450"]] 11 11 12 12 A window with the connection parameters will open: 13 13 14 -[[image:1734009713285-258.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height=" 331" width="600"]]14 +[[image:1734009713285-258.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="248" width="450"]] 15 15 16 16 In the Unified monitor launcher window, choose the used CAN-USB adapter and specify the following settings: 17 17 ... ... @@ -36,11 +36,11 @@ 36 36 37 37 == Changing device parameters == 38 38 39 -The BMS IMD 1.xparameters are summarized in the "Settings" tab of the "Unified monitor" window.39 +The BMS IMD parameters are summarized in the "Settings" tab of the "Unified monitor" window. 40 40 41 41 === Insulation measurement parameters === 42 42 43 -To change the internal parameters of the BMS IMD 1.x, select the «IMD» section:43 +To change the internal parameters of the BMS IMD, select the «IMD» section: 44 44 45 45 [[image:1734009713290-935.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="350" width="600"]] 46 46 ... ... @@ -75,7 +75,7 @@ 75 75 76 76 (% class="box infomessage" %) 77 77 ((( 78 -To apply new settings please restart the BMS IMD 1.xdevice.78 +To apply new settings please restart the BMS IMD device. 79 79 ))) 80 80 81 81 == Reading device status == ... ... @@ -122,7 +122,7 @@ 122 122 123 123 == Indication of device work == 124 124 125 -The BMS IMD 1.xdevice has two LED indicators MODE and ERR.125 +The BMS IMD device has two LED indicators MODE and ERR. 126 126 127 127 The MODE indicator is green and allows you to determine the operating stage of the device by its blinking frequency: 128 128