Changes for page 3. Configuration

Last modified by Admin on 2025/03/03 17:35

From version 7.2
edited by Admin
on 2024/12/12 13:43
Change comment: Update document after refactoring.
To version 8.1
edited by Admin
on 2024/12/12 13:45
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -47,11 +47,11 @@
47 47  In this section:
48 48  
49 49  * Always allow work – a flag to enable work permanently;
50 -* Control via PDO – a flag that allows to control the device using a PDO message (see the BMS IMD 1.x CANopen protocol” document);
50 +* Control via PDO – a flag that allows to control the device using a PDO message (see [[CANopen protocol>>doc:Battery management systems.BMS IMD.4\. CANopen protocol.WebHome]]);
51 51  * Alarm resistance, kOhm – resistance value which indicate the resistance fault and triggers discrete output OUT_ERROR, kOhm;
52 52  * Warning resistance, kOhm – resistance value which triggers the low resistance warning, kOhm;
53 -* Transition timeout – a maximum time of the measurement transient process, after which a Timeout error will be generated (see section 4.3), s. This parameter should be increased if there is significant capacitance between the battery buses and the chassis.
54 -* Minimum bus voltage – a battery voltage value below which a Low bus voltage error will be generated (see section 4.3), V.
53 +* Transition timeout – a maximum time of the measurement transient process, after which a Timeout error will be generated (see [[Reading device status>>doc:||anchor="HReadingdevicestatus"]]), s. This parameter should be increased if there is significant capacitance between the battery buses and the chassis.
54 +* Minimum bus voltage – a battery voltage value below which a Low bus voltage error will be generated (see [[Reading device status>>doc:||anchor="HReadingdevicestatus"]]), V.
55 55  
56 56  === Connection parameters ===
57 57