1 1  (% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 2  = Configuration =
3 3  
4 -The BMS IMD is configured over the CAN bus. The device is a slave in the CANopen network. The ElectricDeviceMonitor software is used for configuring and monitoring device via the USB-CAN adapter. This software supports Systec USB-CANmodul1, PEAK PCAN-USB, Marathon CAN-bus-USB и BMS USB-CAN adapters.
4 +The BMS IMD 1.x is configured over the CAN bus. The device is a slave in the CANopen network. The ElectricDeviceMonitor software is used for configuring and monitoring device via the USB-CAN adapter. This software supports Systec USB-CANmodul1, PEAK PCAN-USB, Marathon CAN-bus-USB и BMS USB-CAN adapters.
5 5  
6 6  == Connecting to the device ==
7 7  
8 8  To connect to the device, launch ElectricDeviceMonitor, select "Unified monitor" in the main program window.
9 9  
10 -[[image:Battery management systems.BMS Main 3.3\. Configuration.3\.1 General information.WebHome@1735233230234-960.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="340" width="450"]]
10 +[[image:1734009713280-126.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="435" width="400"]]
11 11  
12 12  A window with the connection parameters will open:
13 13  
14 -[[image:1734009713285-258.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="248" width="450"]]
14 +[[image:1734009713285-258.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="331" width="600"]]
15 15  
16 16  In the Unified monitor launcher window, choose the used CAN-USB adapter and specify the following settings:
17 17  
... ... @@ -20,16 +20,8 @@
20 20  
21 21  and select the “Launch monitor” button.
22 22  
23 -When connected, the device asks for an access password.
23 +When connected, the device asks for an access password. For the "User" account, the default password is "user" (without quotes).
24 24  
25 -Below is the list of available users. Default passwords can be changed in "Device -> Change password" menu.
26 -
27 -|=User|=Default Password|=Description
28 -|Guest|guest|Guest access to view battery state. No permissions to change and view any settings
29 -|User|user|A common user access with permissions to change almost all the settings
30 -|Service|- (by request)|A service account for battery manufacturers. Has access to some additional settings
31 -|Manufacturer|-|This account is used by BMS manufacturer and not accessible for others
32 -
33 33  [[image:1734009713287-917.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="381" width="600"]]
34 34  
35 35  After successful authentication, the device will send settings and state profiles, which will be displayed as two tabs: "Settings" and "State":
... ... @@ -44,11 +44,11 @@
44 44  
45 45  == Changing device parameters ==
46 46  
47 -The BMS IMD parameters are summarized in the "Settings" tab of the "Unified monitor" window.
39 +The BMS IMD 1.x parameters are summarized in the "Settings" tab of the "Unified monitor" window.
48 48  
49 49  === Insulation measurement parameters ===
50 50  
51 -To change the internal parameters of the BMS IMD, select the «IMD» section:
43 +To change the internal parameters of the BMS IMD 1.x, select the «IMD» section:
52 52  
53 53  [[image:1734009713290-935.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="350" width="600"]]
54 54  
... ... @@ -83,7 +83,7 @@
83 83  
84 84  (% class="box infomessage" %)
85 85  (((
86 -To apply new settings please restart the BMS IMD device.
78 +To apply new settings please restart the BMS IMD 1.x device.
87 87  )))
88 88  
89 89  == Reading device status ==
... ... @@ -130,7 +130,7 @@
130 130  
131 131  == Indication of device work ==
132 132  
133 -The BMS IMD device has two LED indicators MODE and ERR.
125 +The BMS IMD 1.x device has two LED indicators MODE and ERR.
134 134  
135 135  The MODE indicator is green and allows you to determine the operating stage of the device by its blinking frequency:
136 136