Changes for page 3. Configuration

Last modified by Admin on 2025/06/23 13:30

From version 11.1
edited by Admin
on 2025/03/03 17:35
Change comment: There is no comment for this version
To version 13.1
edited by Admin
on 2025/06/23 13:30
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -109,6 +109,7 @@
109 109  ** Timeout error – timeout of transition process of measurement;
110 110  ** Anomaly error – the device cannot measure resistance, for example, due to a poor connection to the chassis;
111 111  ** Self test error;
112 +** Chassis break;
112 112  * Insulation status:
113 113  ** No data;
114 114  ** Ok;
... ... @@ -116,10 +116,9 @@
116 116  ** Alarm – resistance is lower than the Alarm resistance;
117 117  * Measurement state – state of measurement procedure:
118 118  ** Idle;
119 -** Chassis connection – chassis is connecting to measuring circuit;
120 -** First stage;
121 -** Offset connection – offset resistors are connecting to measuring circuit;
122 -** Second stage;
120 +** Bus voltage check;
121 +** Chassis connection;
122 +** Bias resistor connection;
123 123  * Resistance calculated – a flag showing that the insulation resistance is calculated;
124 124  * Resistance plus – resistance value between positive line and chassis, Ohm;
125 125  * Resistance minus – resistance value between negative line and chassis, Ohm;