Last modified by Admin on 2025/04/09 08:19

From version 8.1
edited by Admin
on 2025/03/18 12:37
Change comment: There is no comment for this version
To version 2.1
edited by Admin
on 2024/12/12 13:19
Change comment: There is no comment for this version

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -2. Installation and connection
1 +2. Connection
Parent
... ... @@ -1,1 +1,1 @@
1 -Battery management systems.BMS IMD.WebHome
1 +drafts.BMS IMD.WebHome
Content
... ... @@ -1,20 +1,6 @@
1 1  (% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 2  = Connection =
3 3  
4 -== Safety rules ==
5 -
6 -Before use, **configure the system**. Proper operation of the BMS is possible only if it is correctly configured.
7 -
8 -(% class="box warningmessage" %)
9 -(((
10 -The BMS can be connected to batteries with life-threatening and health-hazardous voltage levels. When working with high-voltage batteries, observe electrical safety regulations, use safety glasses, protective clothing, insulated tools and appliances. To prevent the damage of device avoid electrostatic discharges while working with the battery.
11 -)))
12 -
13 -(% class="box errormessage" %)
14 -(((
15 -**The system is not designed to operate with batteries whose total voltage exceeds 900V.**
16 -)))
17 -
18 18  == Installation ==
19 19  
20 20  The mounting location must be protected from mechanical obstacles (dust, dirt, large objects) and water. Device placement should provide easy access for connection.
... ... @@ -25,10 +25,11 @@
25 25  |Overall dimensions (length × width × height), mm|140 × 60 × 14
26 26  |Mounting dimensions (length × width), mm|130 × 50
27 27  |Mounting holes|M3
14 +|Header types|Molex series Micro-Fit
28 28  
29 29  == Headers ==
30 30  
31 -The BMS IMD has two headers for connecting the power line (X3 and X4), a header for connecting external equipment and power supply (X2), a chassis connection header (X1) and a jumper which connects a terminal resistor to the CAN bus (J1).
18 +The BMS IMD 1.x has two headers for connecting the power line (X3 and X4), a header for connecting external equipment and power supply (X2), a chassis connection header (X1) and a jumper which connects a terminal resistor to the CAN bus (J1).
32 32  
33 33  [[image:1734009150915-999.png||data-xwiki-image-style-alignment="center" height="267" width="600"]]
34 34  
... ... @@ -35,8 +35,6 @@
35 35  
36 36  === X1 – header for chassis connection ===
37 37  
38 -Receptacle Housing: Molex 430250200. Terminals: Molex 43030
39 -
40 40  [[image:1734009337118-173.png||data-xwiki-image-style-alignment="center"]]
41 41  
42 42  
... ... @@ -46,8 +46,6 @@
46 46  
47 47  === X2 – header for a top-level controller (rev1.1 only) ===
48 48  
49 -Receptacle Housing: Molex 430250800. Terminals: Molex 43030
50 -
51 51  [[image:1734009150925-152.png||data-xwiki-image-style-alignment="center" height="79" width="120"]]
52 52  
53 53  |**Pin**|**Name**|**Description**
... ... @@ -69,8 +69,6 @@
69 69  
70 70  === X2 – header for a top-level controller (rev1.2 only) ===
71 71  
72 -Receptacle Housing: Molex 430251200. Terminals: Molex 43030
73 -
74 74  [[image:1734009150926-839.png||data-xwiki-image-style-alignment="center" height="92" width="198"]]
75 75  
76 76  |**Pin**|**Name**|**Description**
... ... @@ -90,15 +90,13 @@
90 90  (% class="box infomessage" %)
91 91  (((
92 92  **Notes:**
93 -The **OUT_WORK **signal signals the operation of the device’s main program and is generated when the device is turned on.
94 -The **OUT_ERROR **signal indicates a critical device error or a low insulation resistance value.
95 -The **KEYRUN_1 **and **KEYRUN_2 **signals are equivalent and are intended to trigger the device’s power supply circuit. Can be connected to the V+ device supply line.
74 +The OUT_WORK signal signals the operation of the device’s main program and is generated when the device is turned on.
75 +The OUT_ERROR signal indicates a critical device error or a low insulation resistance value.
76 +The KEYRUN_1 and KEYRUN_2 signals are equivalent and are intended to trigger the device’s power supply circuit. Can be connected to the V+ device supply line.
96 96  )))
97 97  
98 98  === X3 – header for positive line connection ===
99 99  
100 -Receptacle Housing: Molex 436450200. Terminals: Molex 43030
101 -
102 102  [[image:1734009150927-865.png||data-xwiki-image-style-alignment="center" height="69" width="88"]]
103 103  
104 104  |**Pin**|**Name**|**Description**
... ... @@ -107,8 +107,6 @@
107 107  
108 108  === X4 – header for negative line connection ===
109 109  
110 -Receptacle Housing: Molex 436450200. Terminals: Molex 43030
111 -
112 112  [[image:1734009150927-865.png||data-xwiki-image-style-alignment="center" height="69" width="88"]]
113 113  
114 114