Last modified by Admin on 2025/04/09 08:19

From version 6.1
edited by Admin
on 2025/02/20 12:41
Change comment: There is no comment for this version
To version 9.1
edited by Admin
on 2025/03/18 12:38
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,6 +1,20 @@
1 1  (% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 2  = Connection =
3 3  
4 +== Safety rules ==
5 +
6 +Before use, **configure the system**. Proper operation of the BMS IMD is possible only if it is correctly configured.
7 +
8 +(% class="box warningmessage" %)
9 +(((
10 +The BMS can be connected to batteries with life-threatening and health-hazardous voltage levels. When working with high-voltage batteries, observe electrical safety regulations, use safety glasses, protective clothing, insulated tools and appliances. To prevent the damage of device avoid electrostatic discharges while working with the battery.
11 +)))
12 +
13 +(% class="box errormessage" %)
14 +(((
15 +**The system is not designed to operate with batteries whose total voltage exceeds 900V.**
16 +)))
17 +
4 4  == Installation ==
5 5  
6 6  The mounting location must be protected from mechanical obstacles (dust, dirt, large objects) and water. Device placement should provide easy access for connection.
... ... @@ -21,7 +21,7 @@
21 21  
22 22  === X1 – header for chassis connection ===
23 23  
24 -Receptacle Housing: Molex 430250200. Terminals: 43030
38 +Receptacle Housing: Molex 430250200. Terminals: Molex 43030
25 25  
26 26  [[image:1734009337118-173.png||data-xwiki-image-style-alignment="center"]]
27 27  
... ... @@ -32,7 +32,7 @@
32 32  
33 33  === X2 – header for a top-level controller (rev1.1 only) ===
34 34  
35 -Receptacle Housing: Molex 430250800. Terminals: 43030
49 +Receptacle Housing: Molex 430250800. Terminals: Molex 43030
36 36  
37 37  [[image:1734009150925-152.png||data-xwiki-image-style-alignment="center" height="79" width="120"]]
38 38  
... ... @@ -55,7 +55,7 @@
55 55  
56 56  === X2 – header for a top-level controller (rev1.2 only) ===
57 57  
58 -Receptacle Housing: Molex 430251200. Terminals: 43030
72 +Receptacle Housing: Molex 430251200. Terminals: Molex 43030
59 59  
60 60  [[image:1734009150926-839.png||data-xwiki-image-style-alignment="center" height="92" width="198"]]
61 61  
... ... @@ -83,7 +83,7 @@
83 83  
84 84  === X3 – header for positive line connection ===
85 85  
86 -Receptacle Housing: Molex 436450200. Terminals: 43030
100 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030
87 87  
88 88  [[image:1734009150927-865.png||data-xwiki-image-style-alignment="center" height="69" width="88"]]
89 89  
... ... @@ -93,7 +93,7 @@
93 93  
94 94  === X4 – header for negative line connection ===
95 95  
96 -Receptacle Housing: Molex 436450200. Terminals: 43030
110 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030
97 97  
98 98  [[image:1734009150927-865.png||data-xwiki-image-style-alignment="center" height="69" width="88"]]
99 99