... ... @@ -1,1 +1,1 @@
1 -2. Connection
1 +2. Installation and connection
Parent
... ... @@ -1,1 +1,1 @@
1 -drafts.BMS IMD.WebHome
1 +Battery management systems.BMS IMD.WebHome
Content
... ... @@ -15,7 +15,7 @@
15 15  
16 16  == Headers ==
17 17  
18 -The BMS IMD 1.x has two headers for connecting the power line (X3 and X4), a header for connecting external equipment and power supply (X2), a chassis connection header (X1) and a jumper which connects a terminal resistor to the CAN bus (J1).
18 +The BMS IMD has two headers for connecting the power line (X3 and X4), a header for connecting external equipment and power supply (X2), a chassis connection header (X1) and a jumper which connects a terminal resistor to the CAN bus (J1).
19 19  
20 20  [[image:1734009150915-999.png||data-xwiki-image-style-alignment="center" height="267" width="600"]]
21 21  
... ... @@ -22,6 +22,8 @@
22 22  
23 23  === X1 – header for chassis connection ===
24 24  
25 +Receptacle Housing: Molex 430250200. Terminals: 43030
26 +
25 25  [[image:1734009337118-173.png||data-xwiki-image-style-alignment="center"]]
26 26  
27 27  
... ... @@ -31,6 +31,8 @@
31 31  
32 32  === X2 – header for a top-level controller (rev1.1 only) ===
33 33  
36 +Receptacle Housing: Molex 430250800. Terminals: 43030
37 +
34 34  [[image:1734009150925-152.png||data-xwiki-image-style-alignment="center" height="79" width="120"]]
35 35  
36 36  |**Pin**|**Name**|**Description**
... ... @@ -52,6 +52,8 @@
52 52  
53 53  === X2 – header for a top-level controller (rev1.2 only) ===
54 54  
59 +Receptacle Housing: Molex 430251200. Terminals: 43030
60 +
55 55  [[image:1734009150926-839.png||data-xwiki-image-style-alignment="center" height="92" width="198"]]
56 56  
57 57  |**Pin**|**Name**|**Description**
... ... @@ -78,6 +78,8 @@
78 78  
79 79  === X3 – header for positive line connection ===
80 80  
87 +Receptacle Housing: Molex 430250200. Terminals: 43030
88 +
81 81  [[image:1734009150927-865.png||data-xwiki-image-style-alignment="center" height="69" width="88"]]
82 82  
83 83  |**Pin**|**Name**|**Description**
... ... @@ -86,6 +86,8 @@
86 86  
87 87  === X4 – header for negative line connection ===
88 88  
97 +Receptacle Housing: Molex 430250200. Terminals: 43030
98 +
89 89  [[image:1734009150927-865.png||data-xwiki-image-style-alignment="center" height="69" width="88"]]