1. Technical specifications

Version 2.1 by Admin on 2024/12/12 13:08

Technical specifications

BMS IMD is designed to measure the insulation resistance between the positive and negative poles of the tractive system battery and the chassis (ground) of the vehicle.

Specifications

ParameterValue
Supply voltage, V9 to 30
Current consumption @ 12V, mA (maximum)100
Battery voltage range, V20 to 900
Battery current consumption during resistance measurement, mA (maximum)0.1
Measurement range, kOhm10 to 10000
Accuracy, % (maximum)±10
Response time for generating an alarm signal, s (maximum)20
CAN bus speed, kbps125, 250 (default), 500, 1000
Dimensions (length × width × height), mm140 × 60 × 14
Weight, g30 ± 5
Operating temperature range, °С-40 to +85

Rated insulation voltage, AC 50Hz, 1 minute, VRMS (minimum):

1) Between chassis and battery lines, 2) Between chassis and power lines, 3) Between power lines and battery lines

3500

Overall and mounting dimensions

1734008836252-490.png