Technical specifications
BMS IMD is designed to measure the insulation resistance between the positive and negative poles of the tractive system battery and the chassis (ground) of the vehicle.
Specifications
Parameter | Value |
Supply voltage, V | 9 to 30 |
Current consumption @ 12V, mA (maximum) | 100 |
Battery voltage range, V | 20 to 900 |
Battery current consumption during resistance measurement, mA (maximum) | 0.1 |
Measurement range, kOhm | 10 to 10000 |
Accuracy, % (maximum) | ±10 |
Response time for generating an alarm signal, s (maximum) | 20 |
CAN bus speed, kbps | 125, 250 (default), 500, 1000 |
Dimensions (length × width × height), mm | 140 × 60 × 14 |
Weight, g | 30 ± 5 |
Operating temperature range, °С | -40 to +85 |
Rated insulation voltage, AC 50Hz, 1 minute, VRMS (minimum): 1) Between chassis and battery lines, 2) Between chassis and power lines, 3) Between power lines and battery lines | 3500 |
Overall and mounting dimensions