Last modified by Admin on 2025/05/12 11:25

From version 9.1
edited by Admin
on 2025/04/09 08:17
Change comment: There is no comment for this version
To version 7.1
edited by Admin
on 2025/02/20 12:42
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,7 +1,7 @@
1 1  (% data-numbered-headings-start="1" style="--numbered-headings-start: 0;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 2  = Technical specifications =
3 3  
4 -[[image:https://movicomelectric.com/wa-data/public/site/img/14-bms-imd.png||data-xwiki-image-style-alignment="center" height="202" width="576"]]
4 +[[image:1734098621376-965.png||data-xwiki-image-style-alignment="center" height="167" width="450"]]
5 5  
6 6  BMS IMD is designed to measure the insulation resistance between the positive and negative poles of the tractive system battery and the chassis (ground) of the vehicle.
7 7  
... ... @@ -9,8 +9,8 @@
9 9  
10 10  (% style="width:592px" %)
11 11  |(% style="width:394px" %)**Parameter**|(% style="width:195px" %)**Value**
12 -|(% style="width:394px" %)Supply voltage, V|(% style="width:195px" %)9 to 32
13 -|(% style="width:394px" %)Current consumption @ 24V, mA (maximum)|(% style="width:195px" %)50
12 +|(% style="width:394px" %)Supply voltage, V|(% style="width:195px" %)9 to 30
13 +|(% style="width:394px" %)Current consumption @ 12V, mA (maximum)|(% style="width:195px" %)100
14 14  |(% style="width:394px" %)Battery voltage range, V|(% style="width:195px" %)20 to 900
15 15  |(% style="width:394px" %)Battery current consumption during resistance measurement, mA (maximum)|(% style="width:195px" %)0.1
16 16  |(% style="width:394px" %)Measurement range, kOhm|(% style="width:195px" %)10 to 10000
... ... @@ -18,7 +18,7 @@
18 18  |(% style="width:394px" %)Response time for generating an alarm signal, s (maximum)|(% style="width:195px" %)20
19 19  |(% style="width:394px" %)CAN bus speed, kbps|(% style="width:195px" %)125, 250 (default), 500, 1000
20 20  |(% style="width:394px" %)Dimensions (length × width × height), mm|(% style="width:195px" %)140 × 60 × 14
21 -|(% style="width:394px" %)Weight, g|(% style="width:195px" %)50 ± 5
21 +|(% style="width:394px" %)Weight, g|(% style="width:195px" %)30 ± 5
22 22  |(% style="width:394px" %)Operating temperature range, °С|(% style="width:195px" %)-40 to +85
23 23  |(% style="width:394px" %)(((
24 24  Rated insulation voltage, AC 50Hz, 1 minute, V,,RMS,, (minimum):
... ... @@ -30,7 +30,7 @@
30 30  == Overall and mounting dimensions ==
31 31  
32 32  
33 -[[image:1744186656175-812.png||data-xwiki-image-style-alignment="center" height="499" width="707"]]
33 +[[image:1734008836252-490.png||data-xwiki-image-style-alignment="center" height="367" width="533"]]
34 34  
35 35  == Operation description ==
36 36  
1744186656175-812.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -169.3 KB
Content