Changes for page 1. Technical specifications
Last modified by Admin on 2025/05/12 11:25
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,16 +1,16 @@ 1 1 (% data-numbered-headings-start="1" style="--numbered-headings-start: 0;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 2 = Technical specifications = 3 3 4 -[[image:1 734098621376-965.png||data-xwiki-image-style-alignment="center" height="167" width="450"]]4 +[[image:https://movicomelectric.com/wa-data/public/site/img/14-bms-imd.png||data-xwiki-image-style-alignment="center" height="202" width="576"]] 5 5 6 -BMS IMD is designed to measure the insulation resistance between the positive and negative poles of the tractive system battery and the chassis (ground) of the vehicle. 6 +The BMS IMD is designed to measure the insulation resistance between the positive and negative poles of the tractive system battery and the chassis (ground) of the vehicle. 7 7 8 8 == Specifications == 9 9 10 10 (% style="width:592px" %) 11 11 |(% style="width:394px" %)**Parameter**|(% style="width:195px" %)**Value** 12 -|(% style="width:394px" %)Supply voltage, V|(% style="width:195px" %)9 to 3 013 -|(% style="width:394px" %)Current consumption @ 12V, mA (maximum)|(% style="width:195px" %)10012 +|(% style="width:394px" %)Supply voltage, V|(% style="width:195px" %)9 to 32 13 +|(% style="width:394px" %)Current consumption @ 24V, mA (maximum)|(% style="width:195px" %)50 14 14 |(% style="width:394px" %)Battery voltage range, V|(% style="width:195px" %)20 to 900 15 15 |(% style="width:394px" %)Battery current consumption during resistance measurement, mA (maximum)|(% style="width:195px" %)0.1 16 16 |(% style="width:394px" %)Measurement range, kOhm|(% style="width:195px" %)10 to 10000 ... ... @@ -18,7 +18,7 @@ 18 18 |(% style="width:394px" %)Response time for generating an alarm signal, s (maximum)|(% style="width:195px" %)20 19 19 |(% style="width:394px" %)CAN bus speed, kbps|(% style="width:195px" %)125, 250 (default), 500, 1000 20 20 |(% style="width:394px" %)Dimensions (length × width × height), mm|(% style="width:195px" %)140 × 60 × 14 21 -|(% style="width:394px" %)Weight, g|(% style="width:195px" %) 30 ± 521 +|(% style="width:394px" %)Weight, g|(% style="width:195px" %)50 ± 5 22 22 |(% style="width:394px" %)Operating temperature range, °С|(% style="width:195px" %)-40 to +85 23 23 |(% style="width:394px" %)((( 24 24 Rated insulation voltage, AC 50Hz, 1 minute, V,,RMS,, (minimum): ... ... @@ -30,7 +30,7 @@ 30 30 == Overall and mounting dimensions == 31 31 32 32 33 -[[image:17 34008836252-490.png||data-xwiki-image-style-alignment="center" height="367" width="533"]]33 +[[image:1744186656175-812.png||data-xwiki-image-style-alignment="center" height="499" width="707"]] 34 34 35 35 == Operation description == 36 36
- 1744186656175-812.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +169.3 KB - Content