Wiki source code of 4. Indication

Version 4.1 by Admin on 2024/12/13 15:24

Show last authors
1 (% data-numbered-headings-start="4" style="--numbered-headings-start: 3;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 = Indication =
3
4 == No connection with BMS ==
5
6 If there are no Heartbeat messages from the BMS controller over the CAN bus the following message will be output on the display:
7
8 [[image:1734103363078-519.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]](% style="display:none" %)
9
10 ound signals are not emitted in this case.
11
12 == BMS initialization ==
13
14 If the connection with the BMS controller is established and the BMS is in the initialization mode (during the initialization the current sensor is calibrating and the BMS Logic boards searching is performed), the second line of the display will contain zero values of the voltage, current and temperature:
15
16 [[image:1734102855336-616.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]]
17
18 Sound signals are not emitted in this case.
19
20 == Battery discharging ==
21
22 If the battery is in the discharging mode (the current is zero or negative) and there are no errors, the first line of the display will contain the charge level and the second line will contain battery parameters: voltage, current and minimum/maximum temperature:
23
24 [[image:1734102877861-815.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]]
25
26 (% contenteditable="false" style="background-image:url(https://docs.movicomelectric.com/webjars/wiki%3Axwiki/xwiki-platform-ckeditor-webjar/16.9.0/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" tabindex="-1" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]]
27
28 [[image:1734102885576-298.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]]
29
30 (% class="box infomessage" %)
31 (((
32 **//Note: //**Views with the minimum and maximum temperatures are changing every 2 seconds. To change them manually press the button on the device or an external button connected to the P6 header.
33 )))
34
35 If the battery charge level is below the value set in the **//Low battery level signal (single beep)//** group, the device will emit a sound signal about the low battery charge level.
36
37 If the battery charge level is below the value set in the **//Battery discharged signal (three beeps)//** group, the device will emit three sound signals alarming that the battery is empty.
38
39 == Battery charging ==
40
41 The device emits a sound signal if the charger is connected to the battery. Duration of the signal is set by the //Signal duration on charger connected// parameter. The following message will be output to the display in this case:
42
43 [[image:1734102931997-130.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]]The device emits two signals if the charger is disconnected from the battery. Duration of the signals is set by the //Signal duration on charger disconnected// parameter. The following message will be output to the display in this case:
44
45 [[image:1734102958659-972.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]]
46
47 If the battery is charging the following animation will appear on the display:
48
49 [[image:1734102981350-437.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]]
50 [[image:1734103175570-572.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]]
51 [[image:1734103197404-229.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]]
52 [[image:1734103225567-898.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]]
53 [[image:1734103241852-723.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]]
54
55 == Indication of errors ==
56
57 If there are errors selected by the //Errors filter// (see **//Display options //**group), names or codes of errors will be output to the display. In this case a loud sound signal is periodically emitted.
58
59 [[image:1734103291589-278.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]]
60 [[image:1734103305252-869.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]]
61
62 If the number of errors is greater than three, a list of errors will be output page by page. Turning pages will be performed automatically every 2 seconds.  It is also available changing pages manually using the button on the device or an external button connected to the P6 header.
63
64
65 Errors names and codes are in the table below.
66
67 |**Error code**|**Error name**|**Description**
68 |ACK|Need ACK|Acknowledge of errors is needed
69 |ADC|ADC error|Wrong values from the ADC
70 |BC|Battery cover|Battery cover is opened
71 |CCC|CH cont. cycle|Charge contactor switches too frequency
72 |CCF|CH cont. feed.|Wrong feedback signal from the charging contactor
73 |CEL|Cell count|Wrong number of cells
74 |CER|Critical error|Critical error
75 |CHT|Cont. hi. temp.|Hight temperature of a contactor
76 |COM|Combilift offl.|No connection with the Combilift forklift
77 |CRO|Crown error|Crown forklift error
78 |CSE|Current sensor|Current sensor is shorted or opened
79 |DCC|DCH cont. cycle|Discharge contactor switches too frequency
80 |DCF|DCH cont. feed.|Wrong feedback signal from the discharging contactor
81 |FSE|FS error|Filesystem on an SD card is corrupted
82 |HCT|High CH temp.|Battery temperature is too high for charging
83 |HDT|High DCH temp.|Battery temperature is too high for discharging
84 |HH|High humidity|High humidity
85 |HYG|HYG offline|No connection with the HYG forklift
86 |LCT|Low CH temp.|Battery temperature is too low for charging
87 |LDT|Low DCH temp.|Battery temperature is too low for discharging
88 |LHT|Logic hi. temp.|Temperature of a BMS Logic board is too high
89 |LOF|Logic offline|No connection with a BMS Logic board
90 |LOG|Logic count|Wrong number of BMS Logic boards
91 |MNT|Mount error|SD card is not mounted
92 |NTS|No temp. sens.|No temperature sensors connected to a BMS Logic
93 |OC|Overcurrent|High current
94 |OV|Overvoltage|High voltage
95 |SET|Settings error|Checksum of settings is wrong
96 |SHC|Short circuit|Short circuit
97 |SHE|Shunt error|Internal error of the shunt sensor
98 |SHO|Shunt offline|No connection with the shunt sensor
99 |SPI|Spirit offline|No connection with the Spirit truck
100 |STC|Stuck contactor|Contactor is stuck
101 |TSS|Shorted temp.|A temperature sensor connected to a BMS Logic is shorted
102 |UCH|Unallowable CH|Charging the battery through the discharging circuit
103 |UV|Undervoltage|Low voltage
104 |WA|Water|Water in the battery
105 |WDT|WDT reset|Watchdog timer reset the BMS
106