Changes for page 4. Indication
Last modified by Admin on 2025/02/27 15:48
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -52,15 +52,53 @@ 52 52 53 53 == Indication of errors == 54 54 55 -If there are errors selected by the //Errors filter s// (see **//Display options //**groupin [[Configuration>>doc:Battery management systems.BMS Display.3\. Configuration.WebHome]]), names or codes of errors will be output to the display. In this case a loud sound signal is periodically emitted.55 +If there are errors selected by the //Errors filter// (see **//Display options //**group), names or codes of errors will be output to the display. In this case a loud sound signal is periodically emitted. 56 56 57 57 [[image:1734103291589-278.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]] 58 58 [[image:1734103305252-869.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]] 59 59 60 -If the number of errors is greater than three, a list of errors will be output page by page. Turning pages will be performed automatically every 2 seconds. It is also available changing pages manually using the button on the device or an external button connected to the P6 header. 60 +If the number of errors is greater than three, a list of errors will be output page by page. Turning pages will be performed automatically every 2 seconds. It is also available changing pages manually using the button on the device or an external button connected to the P6 header. 61 61 62 -Errors shortnames andabbreviations for BMS Main 2.1, BMS Mini, BMS Mini S andBMS Main 3 arehown[[here>>doc:Battery managementsystems.Additionalinformation.1\. Batterycontrollers\: signals anderrors.WebHome||anchor="HErrors"]].62 +Errors names and codes are in the table below. 63 63 64 -Errors short names and abbreviations for BMS Main X and BMS Main 3X are shown [[here>>doc:Battery management systems.Additional information.2\. Strings controllers\: signals and errors.WebHome||anchor="HErrors"]]. 64 +|**Error code**|**Error name**|**Description** 65 +|ACK|Need ACK|Acknowledge of errors is needed 66 +|ADC|ADC error|Wrong values from the ADC 67 +|BC|Battery cover|Battery cover is opened 68 +|CCC|CH cont. cycle|Charge contactor switches too frequency 69 +|CCF|CH cont. feed.|Wrong feedback signal from the charging contactor 70 +|CEL|Cell count|Wrong number of cells 71 +|CER|Critical error|Critical error 72 +|CHT|Cont. hi. temp.|Hight temperature of a contactor 73 +|COM|Combilift offl.|No connection with the Combilift forklift 74 +|CRO|Crown error|Crown forklift error 75 +|CSE|Current sensor|Current sensor is shorted or opened 76 +|DCC|DCH cont. cycle|Discharge contactor switches too frequency 77 +|DCF|DCH cont. feed.|Wrong feedback signal from the discharging contactor 78 +|FSE|FS error|Filesystem on an SD card is corrupted 79 +|HCT|High CH temp.|Battery temperature is too high for charging 80 +|HDT|High DCH temp.|Battery temperature is too high for discharging 81 +|HH|High humidity|High humidity 82 +|HYG|HYG offline|No connection with the HYG forklift 83 +|LCT|Low CH temp.|Battery temperature is too low for charging 84 +|LDT|Low DCH temp.|Battery temperature is too low for discharging 85 +|LHT|Logic hi. temp.|Temperature of a BMS Logic board is too high 86 +|LOF|Logic offline|No connection with a BMS Logic board 87 +|LOG|Logic count|Wrong number of BMS Logic boards 88 +|MNT|Mount error|SD card is not mounted 89 +|NTS|No temp. sens.|No temperature sensors connected to a BMS Logic 90 +|OC|Overcurrent|High current 91 +|OV|Overvoltage|High voltage 92 +|SET|Settings error|Checksum of settings is wrong 93 +|SHC|Short circuit|Short circuit 94 +|SHE|Shunt error|Internal error of the shunt sensor 95 +|SHO|Shunt offline|No connection with the shunt sensor 96 +|SPI|Spirit offline|No connection with the Spirit truck 97 +|STC|Stuck contactor|Contactor is stuck 98 +|TSS|Shorted temp.|A temperature sensor connected to a BMS Logic is shorted 99 +|UCH|Unallowable CH|Charging the battery through the discharging circuit 100 +|UV|Undervoltage|Low voltage 101 +|WA|Water|Water in the battery 102 +|WDT|WDT reset|Watchdog timer reset the BMS 65 65 66 66