Changes for page 4. Indication
Last modified by Admin on 2025/02/27 15:48
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -52,53 +52,13 @@ 52 52 53 53 == Indication of errors == 54 54 55 -If there are errors selected by the //Errors filter// (see **//Display options //**group), names or codes of errors will be output to the display. In this case a loud sound signal is periodically emitted. 55 +If there are errors selected by the //Errors filters// (see **//Display options //**group in [[Configuration>>doc:Battery management systems.BMS Display.3\. Configuration.WebHome]]), names or codes of errors will be output to the display. In this case a loud sound signal is periodically emitted. 56 56 57 57 [[image:1734103291589-278.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]] 58 58 [[image:1734103305252-869.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]] 59 59 60 -If the number of errors is greater than three, a list of errors will be output page by page. Turning pages will be performed automatically every 2 seconds. 60 +If the number of errors is greater than three, a list of errors will be output page by page. Turning pages will be performed automatically every 2 seconds. It is also available changing pages manually using the button on the device or an external button connected to the P6 header. 61 61 62 -Errors names and codesarethetablebelow.62 +Errors short names and abbreviations for BMS Main 2.1, BMS Mini, B 63 63 64 -|**Error code**|**Error name**|**Description** 65 -|ACK|Need ACK|Acknowledge of errors is needed 66 -|ADC|ADC error|Wrong values from the ADC 67 -|BC|Battery cover|Battery cover is opened 68 -|CCC|CH cont. cycle|Charge contactor switches too frequency 69 -|CCF|CH cont. feed.|Wrong feedback signal from the charging contactor 70 -|CEL|Cell count|Wrong number of cells 71 -|CER|Critical error|Critical error 72 -|CHT|Cont. hi. temp.|Hight temperature of a contactor 73 -|COM|Combilift offl.|No connection with the Combilift forklift 74 -|CRO|Crown error|Crown forklift error 75 -|CSE|Current sensor|Current sensor is shorted or opened 76 -|DCC|DCH cont. cycle|Discharge contactor switches too frequency 77 -|DCF|DCH cont. feed.|Wrong feedback signal from the discharging contactor 78 -|FSE|FS error|Filesystem on an SD card is corrupted 79 -|HCT|High CH temp.|Battery temperature is too high for charging 80 -|HDT|High DCH temp.|Battery temperature is too high for discharging 81 -|HH|High humidity|High humidity 82 -|HYG|HYG offline|No connection with the HYG forklift 83 -|LCT|Low CH temp.|Battery temperature is too low for charging 84 -|LDT|Low DCH temp.|Battery temperature is too low for discharging 85 -|LHT|Logic hi. temp.|Temperature of a BMS Logic board is too high 86 -|LOF|Logic offline|No connection with a BMS Logic board 87 -|LOG|Logic count|Wrong number of BMS Logic boards 88 -|MNT|Mount error|SD card is not mounted 89 -|NTS|No temp. sens.|No temperature sensors connected to a BMS Logic 90 -|OC|Overcurrent|High current 91 -|OV|Overvoltage|High voltage 92 -|SET|Settings error|Checksum of settings is wrong 93 -|SHC|Short circuit|Short circuit 94 -|SHE|Shunt error|Internal error of the shunt sensor 95 -|SHO|Shunt offline|No connection with the shunt sensor 96 -|SPI|Spirit offline|No connection with the Spirit truck 97 -|STC|Stuck contactor|Contactor is stuck 98 -|TSS|Shorted temp.|A temperature sensor connected to a BMS Logic is shorted 99 -|UCH|Unallowable CH|Charging the battery through the discharging circuit 100 -|UV|Undervoltage|Low voltage 101 -|WA|Water|Water in the battery 102 -|WDT|WDT reset|Watchdog timer reset the BMS 103 - 104 104