Changes for page 4. Indication
Last modified by Admin on 2025/02/27 15:48
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -7,7 +7,7 @@ 7 7 8 8 [[image:1734103363078-519.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]](% style="display:none" %) 9 9 10 - Sound signals are not emitted in this case.10 +ound signals are not emitted in this case. 11 11 12 12 == BMS initialization == 13 13 ... ... @@ -23,6 +23,8 @@ 23 23 24 24 [[image:1734102877861-815.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]] 25 25 26 +(% contenteditable="false" style="background-image:url(https://docs.movicomelectric.com/webjars/wiki%3Axwiki/xwiki-platform-ckeditor-webjar/16.9.0/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" tabindex="-1" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]] 27 + 26 26 [[image:1734102885576-298.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]] 27 27 28 28 (% class="box infomessage" %) ... ... @@ -59,46 +59,47 @@ 59 59 60 60 If the number of errors is greater than three, a list of errors will be output page by page. Turning pages will be performed automatically every 2 seconds. It is also available changing pages manually using the button on the device or an external button connected to the P6 header. 61 61 64 + 62 62 Errors names and codes are in the table below. 63 63 64 64 |**Error code**|**Error name**|**Description** 65 -|ACK|Need ACK|Acknowledge of errors is needed 66 -|ADC|ADC error|Wrong values from the ADC 67 -|BC|Battery cover|Battery cover is opened 68 -|CCC|CH cont. cycle|Charge contactor switches too frequency 69 -|CCF|CH cont. feed.|Wrong feedback signal from the charging contactor 70 -|CEL|Cell count|Wrong number of cells 71 -|CER|Critical error|Critical error 72 -|CHT|Cont. hi. temp.|Hight temperature of a contactor 73 -|COM|Combilift offl.|No connection with the Combilift forklift 74 -|CRO|Crown error|Crown forklift error 75 -|CSE|Current sensor|Current sensor is shorted or opened 76 -|DCC|DCH cont. cycle|Discharge contactor switches too frequency 77 -|DCF|DCH cont. feed.|Wrong feedback signal from the discharging contactor 78 -|FSE|FS error|Filesystem on an SD card is corrupted 79 -|HCT|High CH temp.|Battery temperature is too high for charging 68 +|OC|Overcurrent|High current 69 +|UV|Undervoltage|Low voltage 70 +|OV|Overvoltage|High voltage 71 +|LDT|Low DCH temp.|Battery temperature is too low for discharging 80 80 |HDT|High DCH temp.|Battery temperature is too high for discharging 73 +|BC|Battery cover|Battery cover is opened 81 81 |HH|High humidity|High humidity 82 -|HYG|HYG offline|No connection with the HYG forklift 83 -|LCT|Low CH temp.|Battery temperature is too low for charging 84 -|LDT|Low DCH temp.|Battery temperature is too low for discharging 75 +|WA|Water|Water in the battery 85 85 |LHT|Logic hi. temp.|Temperature of a BMS Logic board is too high 86 86 |LOF|Logic offline|No connection with a BMS Logic board 87 -| LOG|Logiccount|Wrongnumberf BMS Logic boards88 -| MNT|Mounterror|SD card is notmounted89 -| NTS|No temp.sens.|Notemperature sensors connectedtoa BMS Logic90 -| OC|Overcurrent|Highcurrent91 -| OV|Overvoltage|Highvoltage92 -| SET|Settings error|Checksum ofsettingsiswrong78 +|CER|Critical error|Critical error 79 +|CRO|Crown error|Crown forklift error 80 +|CEL|Cell count|Wrong number of cells 81 +|HYG|HYG offline|No connection with the HYG forklift 82 +|ACK|Need ACK|Acknowledge of errors is needed 83 +|COM|Combilift offl.|No connection with the Combilift forklift 93 93 |SHC|Short circuit|Short circuit 94 -|SHE|Shunt error|Internal error of the shunt sensor 85 +|CHT|Cont. hi. temp.|Hight temperature of a contactor 86 +|LOG|Logic count|Wrong number of BMS Logic boards 87 +|ADC|ADC error|Wrong values from the ADC 88 +|CSE|Current sensor|Current sensor is shorted or opened 89 +|CCC|CH cont. cycle|Charge contactor switches too frequency 90 +|DCC|DCH cont. cycle|Discharge contactor switches too frequency 95 95 |SHO|Shunt offline|No connection with the shunt sensor 96 -|SPI|Spirit offline|No connection with the Spirit truck 97 -|STC|Stuck contactor|Contactor is stuck 92 +|SHE|Shunt error|Internal error of the shunt sensor 93 +|SET|Settings error|Checksum of settings is wrong 94 +|WDT|WDT reset|Watchdog timer reset the BMS 95 +|NTS|No temp. sens.|No temperature sensors connected to a BMS Logic 98 98 |TSS|Shorted temp.|A temperature sensor connected to a BMS Logic is shorted 97 +|SPI|Spirit offline|No connection with the Spirit truck 98 +|LCT|Low CH temp.|Battery temperature is too low for charging 99 +|HCT|High CH temp.|Battery temperature is too high for charging 100 +|MNT|Mount error|SD card is not mounted 101 +|FSE|FS error|Filesystem on an SD card is corrupted 99 99 |UCH|Unallowable CH|Charging the battery through the discharging circuit 100 -| UV|Undervoltage|Lowvoltage101 -| WA|Water|Water in thebattery102 -| WDT|WDTreset|Watchdogtimer resettheBMS103 +|STC|Stuck contactor|Contactor is stuck 104 +|CCF|CH cont. feed.|Wrong feedback signal from the charging contactor 105 +|DCF|DCH cont. feed.|Wrong feedback signal from the discharging contactor 103 103 104 104