Changes for page 4. Indication
Last modified by Admin on 2025/02/27 15:48
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -7,7 +7,7 @@ 7 7 8 8 [[image:1734103363078-519.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]](% style="display:none" %) 9 9 10 - Sound signals are not emitted in this case.10 +ound signals are not emitted in this case. 11 11 12 12 == BMS initialization == 13 13 ... ... @@ -23,6 +23,8 @@ 23 23 24 24 [[image:1734102877861-815.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]] 25 25 26 +(% contenteditable="false" style="background-image:url(https://docs.movicomelectric.com/webjars/wiki%3Axwiki/xwiki-platform-ckeditor-webjar/16.9.0/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" tabindex="-1" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]] 27 + 26 26 [[image:1734102885576-298.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]] 27 27 28 28 (% class="box infomessage" %) ... ... @@ -59,46 +59,47 @@ 59 59 60 60 If the number of errors is greater than three, a list of errors will be output page by page. Turning pages will be performed automatically every 2 seconds. It is also available changing pages manually using the button on the device or an external button connected to the P6 header. 61 61 64 + 62 62 Errors names and codes are in the table below. 63 63 64 -|**Error code**|**Errorname**|**Description**65 -| ACK|Need ACK|Acknowledgeof errors is needed66 -| ADC|ADCerror|Wrongvalues fromtheADC67 -| BC|Battery cover|Battery coverisopened68 -|C CC|CHcont. cycle|Chargecontactorswitches too frequency69 -|C CF|CHcont. feed.|Wrongfeedbacksignalfromthechargingcontactor70 -| CEL|Cellcount|Wrongnumberofcells71 -| CER|Criticalerror|Criticalerror72 -| CHT|Cont.hi.temp.|Hight temperatureofacontactor73 -| COM|Combiliftoffl.|No connectionwiththeCombiliftforklift74 -| CRO|Crownerror|Crownforklifterror75 -|C SE|Currentsensor|Currentsensoris shortedoropened76 -| DCC|DCH cont.cycle|Discharge contactorswitchestoo frequency77 -| DCF|DCHcont. feed.|Wrongfeedback signal fromthedischargingcontactor78 -| FSE|FSerror|FilesystemonanSDcardiscorrupted79 -| HCT|HighCH temp.|Batterytemperature is too high forcharging80 -| HDT|HighDCHtemp.|Batterytemperatureistoohighfordischarging81 -| HH|Highhumidity|Highhumidity82 -| HYG|HYGoffline|No connectionwith theHYG forklift83 -|L CT|LowCHtemp.|Batterytemperatureis toolowforcharging84 -| LDT|Low DCHtemp.|Batterytemperatureistoo lowfordischarging85 -| LHT|Logic hi.temp.|Temperature ofa BMS Logicboardis toohigh86 -| LOF|Logicoffline|Noconnectionwitha BMS Logic board87 -| LOG|Logiccount|Wrongnumberof BMS Logicboards88 -| MNT|Mounterror|SDcardisnotmounted89 -| NTS|Notemp.sens.|Nomperaturesensorsconnectedtoa BMS Logic90 -| OC|Overcurrent|Highcurrent91 -| OV|Overvoltage|Highvoltage92 -| SET|Settings error|Checksumof settingsiswrong93 -|S HC|Shortcircuit|Short circuit94 -|S HE|Shunterror|Internalerroroftheshuntsensor95 -| SHO|Shuntoffline|No connection withthe shuntsensor96 -| SPI|Spiritoffline|Noconnection withtheSpirit truck97 -| STC|Stuck contactor|Contactor isstuck98 -| TSS|Shortedtemp.|A temperature sensorconnectedto aBMSLogic isshorted99 -|U CH|Unallowable CH|Charging the battery through the discharging circuit100 -| UV|Undervoltage|Lowvoltage101 -| WA|Water|Water in thebattery102 -| WDT|WDTreset|Watchdogtimer resettheBMS67 +|**Error name**|**Error code**|**Description** 68 +|Overcurrent|OC|High current 69 +|Undervoltage|UV|Low voltage 70 +|Overvoltage|OV|High voltage 71 +|Low DCH temp.|LDT|Battery temperature is too low for discharging 72 +|High DCH temp.|HDT|Battery temperature is too high for discharging 73 +|Battery cover|BC|Battery cover is opened 74 +|High humidity|HH|High humidity 75 +|Water|WA|Water in the battery 76 +|Logic hi. temp.|LHT|Temperature of a BMS Logic board is too high 77 +|Logic offline|LOF|No connection with a BMS Logic board 78 +|Critical error|CER|Critical error 79 +|Crown error|CRO|Crown forklift error 80 +|Cell count|CEL|Wrong number of cells 81 +|HYG offline|HYG|No connection with the HYG forklift 82 +|Need ACK|ACK|Acknowledge of errors is needed 83 +|Combilift offl.|COM|No connection with the Combilift forklift 84 +|Short circuit|SHC|Short circuit 85 +|Cont. hi. temp.|CHT|Hight temperature of a contactor 86 +|Logic count|LOG|Wrong number of BMS Logic boards 87 +|ADC error|ADC|Wrong values from the ADC 88 +|Current sensor|CSE|Current sensor is shorted or opened 89 +|CH cont. cycle|CCC|Charge contactor switches too frequency 90 +|DCH cont. cycle|DCC|Discharge contactor switches too frequency 91 +|Shunt offline|SHO|No connection with the shunt sensor 92 +|Shunt error|SHE|Internal error of the shunt sensor 93 +|Settings error|SET|Checksum of settings is wrong 94 +|WDT reset|WDT|Watchdog timer reset the BMS 95 +|No temp. sens.|NTS|No temperature sensors connected to a BMS Logic 96 +|Shorted temp.|TSS|A temperature sensor connected to a BMS Logic is shorted 97 +|Spirit offline|SPI|No connection with the Spirit truck 98 +|Low CH temp.|LCT|Battery temperature is too low for charging 99 +|High CH temp.|HCT|Battery temperature is too high for charging 100 +|Mount error|MNT|SD card is not mounted 101 +|FS error|FSE|Filesystem on an SD card is corrupted 102 +|Unallowable CH|UCH|Charging the battery through the discharging circuit 103 +|Stuck contactor|STC|Contactor is stuck 104 +|CH cont. feed.|CCF|Wrong feedback signal from the charging contactor 105 +|DCH cont. feed.|DCF|Wrong feedback signal from the discharging contactor 103 103 104 104