Changes for page 4. Indication

Last modified by Admin on 2025/02/27 15:48

From version 5.1
edited by Admin
on 2024/12/13 15:24
Change comment: There is no comment for this version
To version 8.1
edited by Admin
on 2025/02/27 15:39
Change comment: There is no comment for this version

Summary

Details

Page properties
Parent
... ... @@ -1,1 +1,1 @@
1 -drafts.BMS Display.WebHome
1 +Battery management systems.BMS Display.WebHome
Content
... ... @@ -7,7 +7,7 @@
7 7  
8 8  [[image:1734103363078-519.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]](% style="display:none" %)
9 9  
10 -ound signals are not emitted in this case.
10 +Sound signals are not emitted in this case.
11 11  
12 12  == BMS initialization ==
13 13  
... ... @@ -23,8 +23,6 @@
23 23  
24 24  [[image:1734102877861-815.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]]
25 25  
26 -(% contenteditable="false" style="background-image:url(https://docs.movicomelectric.com/webjars/wiki%3Axwiki/xwiki-platform-ckeditor-webjar/16.9.0/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" tabindex="-1" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]]
27 -
28 28  [[image:1734102885576-298.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]]
29 29  
30 30  (% class="box infomessage" %)
... ... @@ -54,53 +54,15 @@
54 54  
55 55  == Indication of errors ==
56 56  
57 -If there are errors selected by the //Errors filter// (see **//Display options //**group), names or codes of errors will be output to the display. In this case a loud sound signal is periodically emitted.
55 +If there are errors selected by the //Errors filters// (see **//Display options //**group in [[Configuration>>doc:Battery management systems.BMS Display.3\. Configuration.WebHome]]), names or codes of errors will be output to the display. In this case a loud sound signal is periodically emitted.
58 58  
59 59  [[image:1734103291589-278.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]]
60 60  [[image:1734103305252-869.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]]
61 61  
62 -If the number of errors is greater than three, a list of errors will be output page by page. Turning pages will be performed automatically every 2 seconds.  It is also available changing pages manually using the button on the device or an external button connected to the P6 header.
60 +If the number of errors is greater than three, a list of errors will be output page by page. Turning pages will be performed automatically every 2 seconds. It is also available changing pages manually using the button on the device or an external button connected to the P6 header.
63 63  
64 -Errors names and codes are in the table below.
62 +Errors short names and abbreviations for BMS Main 2.1, BMS Mini, BMS Mini S and BMS Main 3 are shown [[here>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HErrors"]].
65 65  
66 -|**Error code**|**Error name**|**Description**
67 -|ACK|Need ACK|Acknowledge of errors is needed
68 -|ADC|ADC error|Wrong values from the ADC
69 -|BC|Battery cover|Battery cover is opened
70 -|CCC|CH cont. cycle|Charge contactor switches too frequency
71 -|CCF|CH cont. feed.|Wrong feedback signal from the charging contactor
72 -|CEL|Cell count|Wrong number of cells
73 -|CER|Critical error|Critical error
74 -|CHT|Cont. hi. temp.|Hight temperature of a contactor
75 -|COM|Combilift offl.|No connection with the Combilift forklift
76 -|CRO|Crown error|Crown forklift error
77 -|CSE|Current sensor|Current sensor is shorted or opened
78 -|DCC|DCH cont. cycle|Discharge contactor switches too frequency
79 -|DCF|DCH cont. feed.|Wrong feedback signal from the discharging contactor
80 -|FSE|FS error|Filesystem on an SD card is corrupted
81 -|HCT|High CH temp.|Battery temperature is too high for charging
82 -|HDT|High DCH temp.|Battery temperature is too high for discharging
83 -|HH|High humidity|High humidity
84 -|HYG|HYG offline|No connection with the HYG forklift
85 -|LCT|Low CH temp.|Battery temperature is too low for charging
86 -|LDT|Low DCH temp.|Battery temperature is too low for discharging
87 -|LHT|Logic hi. temp.|Temperature of a BMS Logic board is too high
88 -|LOF|Logic offline|No connection with a BMS Logic board
89 -|LOG|Logic count|Wrong number of BMS Logic boards
90 -|MNT|Mount error|SD card is not mounted
91 -|NTS|No temp. sens.|No temperature sensors connected to a BMS Logic
92 -|OC|Overcurrent|High current
93 -|OV|Overvoltage|High voltage
94 -|SET|Settings error|Checksum of settings is wrong
95 -|SHC|Short circuit|Short circuit
96 -|SHE|Shunt error|Internal error of the shunt sensor
97 -|SHO|Shunt offline|No connection with the shunt sensor
98 -|SPI|Spirit offline|No connection with the Spirit truck
99 -|STC|Stuck contactor|Contactor is stuck
100 -|TSS|Shorted temp.|A temperature sensor connected to a BMS Logic is shorted
101 -|UCH|Unallowable CH|Charging the battery through the discharging circuit
102 -|UV|Undervoltage|Low voltage
103 -|WA|Water|Water in the battery
104 -|WDT|WDT reset|Watchdog timer reset the BMS
64 +Errors short names and abbreviations for BMS Main X and BMS Main 3X are shown [[here>>doc:Battery management systems.Additional information.2\. Strings controllers\: signals and errors.WebHome||anchor="HErrors"]].
105 105  
106 106