Changes for page 4. Indication
Last modified by Admin on 2025/02/27 15:48
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -65,43 +65,43 @@ 65 65 Errors names and codes are in the table below. 66 66 67 67 |**Error code**|**Error name**|**Description** 68 -|ACK|Need ACK|Acknowledge of errors is needed 69 -|ADC|ADC error|Wrong values from the ADC 70 -|BC|Battery cover|Battery cover is opened 71 -|CCC|CH cont. cycle|Charge contactor switches too frequency 72 -|CCF|CH cont. feed.|Wrong feedback signal from the charging contactor 73 -|CEL|Cell count|Wrong number of cells 74 -|CER|Critical error|Critical error 75 -|CHT|Cont. hi. temp.|Hight temperature of a contactor 76 -|COM|Combilift offl.|No connection with the Combilift forklift 77 -|CRO|Crown error|Crown forklift error 78 -|CSE|Current sensor|Current sensor is shorted or opened 79 -|DCC|DCH cont. cycle|Discharge contactor switches too frequency 80 -|DCF|DCH cont. feed.|Wrong feedback signal from the discharging contactor 81 -|FSE|FS error|Filesystem on an SD card is corrupted 82 -|HCT|High CH temp.|Battery temperature is too high for charging 68 +|OC|Overcurrent|High current 69 +|UV|Undervoltage|Low voltage 70 +|OV|Overvoltage|High voltage 71 +|LDT|Low DCH temp.|Battery temperature is too low for discharging 83 83 |HDT|High DCH temp.|Battery temperature is too high for discharging 73 +|BC|Battery cover|Battery cover is opened 84 84 |HH|High humidity|High humidity 85 -|HYG|HYG offline|No connection with the HYG forklift 86 -|LCT|Low CH temp.|Battery temperature is too low for charging 87 -|LDT|Low DCH temp.|Battery temperature is too low for discharging 75 +|WA|Water|Water in the battery 88 88 |LHT|Logic hi. temp.|Temperature of a BMS Logic board is too high 89 89 |LOF|Logic offline|No connection with a BMS Logic board 90 -| LOG|Logiccount|Wrongnumberf BMS Logic boards91 -| MNT|Mounterror|SD card is notmounted92 -| NTS|No temp.sens.|Notemperature sensors connectedtoa BMS Logic93 -| OC|Overcurrent|Highcurrent94 -| OV|Overvoltage|Highvoltage95 -| SET|Settings error|Checksum ofsettingsiswrong78 +|CER|Critical error|Critical error 79 +|CRO|Crown error|Crown forklift error 80 +|CEL|Cell count|Wrong number of cells 81 +|HYG|HYG offline|No connection with the HYG forklift 82 +|ACK|Need ACK|Acknowledge of errors is needed 83 +|COM|Combilift offl.|No connection with the Combilift forklift 96 96 |SHC|Short circuit|Short circuit 97 -|SHE|Shunt error|Internal error of the shunt sensor 85 +|CHT|Cont. hi. temp.|Hight temperature of a contactor 86 +|LOG|Logic count|Wrong number of BMS Logic boards 87 +|ADC|ADC error|Wrong values from the ADC 88 +|CSE|Current sensor|Current sensor is shorted or opened 89 +|CCC|CH cont. cycle|Charge contactor switches too frequency 90 +|DCC|DCH cont. cycle|Discharge contactor switches too frequency 98 98 |SHO|Shunt offline|No connection with the shunt sensor 99 -|SPI|Spirit offline|No connection with the Spirit truck 100 -|STC|Stuck contactor|Contactor is stuck 92 +|SHE|Shunt error|Internal error of the shunt sensor 93 +|SET|Settings error|Checksum of settings is wrong 94 +|WDT|WDT reset|Watchdog timer reset the BMS 95 +|NTS|No temp. sens.|No temperature sensors connected to a BMS Logic 101 101 |TSS|Shorted temp.|A temperature sensor connected to a BMS Logic is shorted 97 +|SPI|Spirit offline|No connection with the Spirit truck 98 +|LCT|Low CH temp.|Battery temperature is too low for charging 99 +|HCT|High CH temp.|Battery temperature is too high for charging 100 +|MNT|Mount error|SD card is not mounted 101 +|FSE|FS error|Filesystem on an SD card is corrupted 102 102 |UCH|Unallowable CH|Charging the battery through the discharging circuit 103 -| UV|Undervoltage|Lowvoltage104 -| WA|Water|Water in thebattery105 -| WDT|WDTreset|Watchdogtimer resettheBMS103 +|STC|Stuck contactor|Contactor is stuck 104 +|CCF|CH cont. feed.|Wrong feedback signal from the charging contactor 105 +|DCF|DCH cont. feed.|Wrong feedback signal from the discharging contactor 106 106 107 107