Changes for page 4. Indication

Last modified by Admin on 2025/02/27 15:48

From version 3.1
edited by Admin
on 2024/12/13 15:23
Change comment: There is no comment for this version
To version 4.1
edited by Admin
on 2024/12/13 15:24
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -65,43 +65,43 @@
65 65  Errors names and codes are in the table below.
66 66  
67 67  |**Error code**|**Error name**|**Description**
68 -|OC|Overcurrent|High current
69 -|UV|Undervoltage|Low voltage
70 -|OV|Overvoltage|High voltage
71 -|LDT|Low DCH temp.|Battery temperature is too low for discharging
72 -|HDT|High DCH temp.|Battery temperature is too high for discharging
68 +|ACK|Need ACK|Acknowledge of errors is needed
69 +|ADC|ADC error|Wrong values from the ADC
73 73  |BC|Battery cover|Battery cover is opened
74 -|HH|High humidity|High humidity
75 -|WA|Water|Water in the battery
76 -|LHT|Logic hi. temp.|Temperature of a BMS Logic board is too high
77 -|LOF|Logic offline|No connection with a BMS Logic board
78 -|CER|Critical error|Critical error
79 -|CRO|Crown error|Crown forklift error
71 +|CCC|CH cont. cycle|Charge contactor switches too frequency
72 +|CCF|CH cont. feed.|Wrong feedback signal from the charging contactor
80 80  |CEL|Cell count|Wrong number of cells
81 -|HYG|HYG offline|No connection with the HYG forklift
82 -|ACK|Need ACK|Acknowledge of errors is needed
83 -|COM|Combilift offl.|No connection with the Combilift forklift
84 -|SHC|Short circuit|Short circuit
74 +|CER|Critical error|Critical error
85 85  |CHT|Cont. hi. temp.|Hight temperature of a contactor
86 -|LOG|Logic count|Wrong number of BMS Logic boards
87 -|ADC|ADC error|Wrong values from the ADC
76 +|COM|Combilift offl.|No connection with the Combilift forklift
77 +|CRO|Crown error|Crown forklift error
88 88  |CSE|Current sensor|Current sensor is shorted or opened
89 -|CCC|CH cont. cycle|Charge contactor switches too frequency
90 90  |DCC|DCH cont. cycle|Discharge contactor switches too frequency
91 -|SHO|Shunt offline|No connection with the shunt sensor
92 -|SHE|Shunt error|Internal error of the shunt sensor
93 -|SET|Settings error|Checksum of settings is wrong
94 -|WDT|WDT reset|Watchdog timer reset the BMS
95 -|NTS|No temp. sens.|No temperature sensors connected to a BMS Logic
96 -|TSS|Shorted temp.|A temperature sensor connected to a BMS Logic is shorted
97 -|SPI|Spirit offline|No connection with the Spirit truck
98 -|LCT|Low CH temp.|Battery temperature is too low for charging
80 +|DCF|DCH cont. feed.|Wrong feedback signal from the discharging contactor
81 +|FSE|FS error|Filesystem on an SD card is corrupted
99 99  |HCT|High CH temp.|Battery temperature is too high for charging
83 +|HDT|High DCH temp.|Battery temperature is too high for discharging
84 +|HH|High humidity|High humidity
85 +|HYG|HYG offline|No connection with the HYG forklift
86 +|LCT|Low CH temp.|Battery temperature is too low for charging
87 +|LDT|Low DCH temp.|Battery temperature is too low for discharging
88 +|LHT|Logic hi. temp.|Temperature of a BMS Logic board is too high
89 +|LOF|Logic offline|No connection with a BMS Logic board
90 +|LOG|Logic count|Wrong number of BMS Logic boards
100 100  |MNT|Mount error|SD card is not mounted
101 -|FSE|FS error|Filesystem on an SD card is corrupted
102 -|UCH|Unallowable CH|Charging the battery through the discharging circuit
92 +|NTS|No temp. sens.|No temperature sensors connected to a BMS Logic
93 +|OC|Overcurrent|High current
94 +|OV|Overvoltage|High voltage
95 +|SET|Settings error|Checksum of settings is wrong
96 +|SHC|Short circuit|Short circuit
97 +|SHE|Shunt error|Internal error of the shunt sensor
98 +|SHO|Shunt offline|No connection with the shunt sensor
99 +|SPI|Spirit offline|No connection with the Spirit truck
103 103  |STC|Stuck contactor|Contactor is stuck
104 -|CCF|CH cont. feed.|Wrong feedback signal from the charging contactor
105 -|DCF|DCH cont. feed.|Wrong feedback signal from the discharging contactor
101 +|TSS|Shorted temp.|A temperature sensor connected to a BMS Logic is shorted
102 +|UCH|Unallowable CH|Charging the battery through the discharging circuit
103 +|UV|Undervoltage|Low voltage
104 +|WA|Water|Water in the battery
105 +|WDT|WDT reset|Watchdog timer reset the BMS
106 106  
107 107