Changes for page 4. Indication

Last modified by Admin on 2025/02/27 15:48

From version 2.1
edited by Admin
on 2024/12/13 15:23
Change comment: There is no comment for this version
To version 9.1
edited by Admin
on 2025/02/27 15:46
Change comment: There is no comment for this version

Summary

Details

Page properties
Parent
... ... @@ -1,1 +1,1 @@
1 -drafts.BMS Display.WebHome
1 +Battery management systems.BMS Display.WebHome
Content
... ... @@ -7,7 +7,7 @@
7 7  
8 8  [[image:1734103363078-519.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]](% style="display:none" %)
9 9  
10 -ound signals are not emitted in this case.
10 +Sound signals are not emitted in this case.
11 11  
12 12  == BMS initialization ==
13 13  
... ... @@ -23,8 +23,6 @@
23 23  
24 24  [[image:1734102877861-815.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]]
25 25  
26 -(% contenteditable="false" style="background-image:url(https://docs.movicomelectric.com/webjars/wiki%3Axwiki/xwiki-platform-ckeditor-webjar/16.9.0/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" tabindex="-1" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]]
27 -
28 28  [[image:1734102885576-298.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]]
29 29  
30 30  (% class="box infomessage" %)
... ... @@ -54,54 +54,16 @@
54 54  
55 55  == Indication of errors ==
56 56  
57 -If there are errors selected by the //Errors filter// (see **//Display options //**group), names or codes of errors will be output to the display. In this case a loud sound signal is periodically emitted.
55 +If there are errors selected by the //Errors filters// (see **//Display options //**group in [[Configuration>>doc:Battery management systems.BMS Display.3\. Configuration.WebHome]]), names or codes of errors will be output to the display. In this case a loud sound signal is periodically emitted.
58 58  
59 59  [[image:1734103291589-278.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]]
60 60  [[image:1734103305252-869.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]]
61 61  
62 -If the number of errors is greater than three, a list of errors will be output page by page. Turning pages will be performed automatically every 2 seconds.  It is also available changing pages manually using the button on the device or an external button connected to the P6 header.
60 +If the number of errors is greater than three, a list of errors will be output page by page. Turning pages will be performed automatically every 2 seconds. It is also available changing pages manually using the button on the device or an external button connected to the P6 header.
63 63  
62 +Errors short names and abbreviations are provided by the following links:
64 64  
65 -Errors names and codes are in the table below.
64 +* [[Link>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HErrors"]] for BMS Main 2.1, BMS Mini, BMS Mini S and BMS Main 3;
65 +* [[Link>>doc:Battery management systems.Additional information.2\. Strings controllers\: signals and errors.WebHome||anchor="HErrors"]] for BMS Main X and BMS Main 3X.
66 66  
67 -|**Error name**|**Error code**|**Description**
68 -|Overcurrent|OC|High current
69 -|Undervoltage|UV|Low voltage
70 -|Overvoltage|OV|High voltage
71 -|Low DCH temp.|LDT|Battery temperature is too low for discharging
72 -|High DCH temp.|HDT|Battery temperature is too high for discharging
73 -|Battery cover|BC|Battery cover is opened
74 -|High humidity|HH|High humidity
75 -|Water|WA|Water in the battery
76 -|Logic hi. temp.|LHT|Temperature of a BMS Logic board is too high
77 -|Logic offline|LOF|No connection with a BMS Logic board
78 -|Critical error|CER|Critical error
79 -|Crown error|CRO|Crown forklift error
80 -|Cell count|CEL|Wrong number of cells
81 -|HYG offline|HYG|No connection with the HYG forklift
82 -|Need ACK|ACK|Acknowledge of errors is needed
83 -|Combilift offl.|COM|No connection with the Combilift forklift
84 -|Short circuit|SHC|Short circuit
85 -|Cont. hi. temp.|CHT|Hight temperature of a contactor
86 -|Logic count|LOG|Wrong number of BMS Logic boards
87 -|ADC error|ADC|Wrong values from the ADC
88 -|Current sensor|CSE|Current sensor is shorted or opened
89 -|CH cont. cycle|CCC|Charge contactor switches too frequency
90 -|DCH cont. cycle|DCC|Discharge contactor switches too frequency
91 -|Shunt offline|SHO|No connection with the shunt sensor
92 -|Shunt error|SHE|Internal error of the shunt sensor
93 -|Settings error|SET|Checksum of settings is wrong
94 -|WDT reset|WDT|Watchdog timer reset the BMS
95 -|No temp. sens.|NTS|No temperature sensors connected to a BMS Logic
96 -|Shorted temp.|TSS|A temperature sensor connected to a BMS Logic is shorted
97 -|Spirit offline|SPI|No connection with the Spirit truck
98 -|Low CH temp.|LCT|Battery temperature is too low for charging
99 -|High CH temp.|HCT|Battery temperature is too high for charging
100 -|Mount error|MNT|SD card is not mounted
101 -|FS error|FSE|Filesystem on an SD card is corrupted
102 -|Unallowable CH|UCH|Charging the battery through the discharging circuit
103 -|Stuck contactor|STC|Contactor is stuck
104 -|CH cont. feed.|CCF|Wrong feedback signal from the charging contactor
105 -|DCH cont. feed.|DCF|Wrong feedback signal from the discharging contactor
106 -
107 107