Changes for page 4. Indication
Last modified by Admin on 2025/02/27 15:48
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -61,47 +61,46 @@ 61 61 62 62 If the number of errors is greater than three, a list of errors will be output page by page. Turning pages will be performed automatically every 2 seconds. It is also available changing pages manually using the button on the device or an external button connected to the P6 header. 63 63 64 - 65 65 Errors names and codes are in the table below. 66 66 67 -|**Error name**|**Errorcode**|**Description**68 -| Overcurrent|OC|Highcurrent69 -| Undervoltage|UV|Lowvoltage70 -| Overvoltage|OV|Highvoltage71 -| Low DCH temp.|LDT|Batterytemperatureis toolowfordischarging72 -| High DCH temp.|HDT|Batterytemperatureistoo highfordischarging73 -| Batterycover|BC|Battery coverisopened74 -| High humidity|HH|Highhumidity75 -| Water|WA|Waterinthebattery76 -| Logic hi.temp.|LHT|TemperatureofaBMSLogicboardistoo high77 -| Logic offline|LOF|Noconnectionwitha BMS Logic board78 -|Cr iticalerror|CER|Criticalerror79 -|C rown error|CRO|Crownforkliftrror80 -|C ellcount|CEL|Wrong number ofcells81 -| HYGoffline|HYG|Noconnectionwiththe HYG forklift82 -| Need ACK|ACK|Acknowledgeoferrorsis needed83 -| Combiliftoffl.|COM|Noconnection withtheCombilift forklift84 -| Shortcircuit|SHC|Shortcircuit85 -| Cont. hi. temp.|CHT|Highttemperatureofacontactor86 -|Lo giccount|LOG|Wrongnumber ofBMS Logicboards87 -| ADC error|ADC|Wrongvalues fromthe ADC88 -| Currentsensor|CSE|Currentsensorisshortedoropened89 -| CH cont.cycle|CCC|Chargecontactorswitchestoofrequency90 -| DCHcont. cycle|DCC|Dischargecontactorswitchestoo frequency91 -| Shuntoffline|SHO|Noconnectionwiththeshuntsensor92 -|S hunt error|SHE|Internalerror oftheshuntsensor93 -| Settings error|SET|Checksum of settingsis wrong94 -| WDT reset|WDT|WatchdogtimerresettheBMS95 -| No temp. sens.|NTS|Notemperature sensorsconnectedtoaBMS Logic96 -|Short edtemp.|TSS|A temperature sensorconnectedto a BMS Logics shorted97 -|S piritoffline|SPI|No connectionwiththeSpirittruck98 -| Low CHtemp.|LCT|Batterytemperatureis toolowforcharging99 -| High CH temp.|HCT|Battery temperatureistoohighfor charging100 -| Mounterror|MNT|SD cardisnotmounted101 -| FS error|FSE|FilesystemonanSDcardiscorrupted102 -|Unallowable CH| UCH|Charging the battery through the discharging circuit103 -| Stuck contactor|STC|Contactoris stuck104 -| CH cont. feed.|CCF|Wrongfeedback signalfromthecharging contactor105 -|D CHcont. feed.|DCF|Wrongfeedbacksignalfromthedischarging contactor66 +|**Error code**|**Error name**|**Description** 67 +|ACK|Need ACK|Acknowledge of errors is needed 68 +|ADC|ADC error|Wrong values from the ADC 69 +|BC|Battery cover|Battery cover is opened 70 +|CCC|CH cont. cycle|Charge contactor switches too frequency 71 +|CCF|CH cont. feed.|Wrong feedback signal from the charging contactor 72 +|CEL|Cell count|Wrong number of cells 73 +|CER|Critical error|Critical error 74 +|CHT|Cont. hi. temp.|Hight temperature of a contactor 75 +|COM|Combilift offl.|No connection with the Combilift forklift 76 +|CRO|Crown error|Crown forklift error 77 +|CSE|Current sensor|Current sensor is shorted or opened 78 +|DCC|DCH cont. cycle|Discharge contactor switches too frequency 79 +|DCF|DCH cont. feed.|Wrong feedback signal from the discharging contactor 80 +|FSE|FS error|Filesystem on an SD card is corrupted 81 +|HCT|High CH temp.|Battery temperature is too high for charging 82 +|HDT|High DCH temp.|Battery temperature is too high for discharging 83 +|HH|High humidity|High humidity 84 +|HYG|HYG offline|No connection with the HYG forklift 85 +|LCT|Low CH temp.|Battery temperature is too low for charging 86 +|LDT|Low DCH temp.|Battery temperature is too low for discharging 87 +|LHT|Logic hi. temp.|Temperature of a BMS Logic board is too high 88 +|LOF|Logic offline|No connection with a BMS Logic board 89 +|LOG|Logic count|Wrong number of BMS Logic boards 90 +|MNT|Mount error|SD card is not mounted 91 +|NTS|No temp. sens.|No temperature sensors connected to a BMS Logic 92 +|OC|Overcurrent|High current 93 +|OV|Overvoltage|High voltage 94 +|SET|Settings error|Checksum of settings is wrong 95 +|SHC|Short circuit|Short circuit 96 +|SHE|Shunt error|Internal error of the shunt sensor 97 +|SHO|Shunt offline|No connection with the shunt sensor 98 +|SPI|Spirit offline|No connection with the Spirit truck 99 +|STC|Stuck contactor|Contactor is stuck 100 +|TSS|Shorted temp.|A temperature sensor connected to a BMS Logic is shorted 101 +|UCH|Unallowable CH|Charging the battery through the discharging circuit 102 +|UV|Undervoltage|Low voltage 103 +|WA|Water|Water in the battery 104 +|WDT|WDT reset|Watchdog timer reset the BMS 106 106 107 107