Changes for page 4. Indication
Last modified by Admin on 2025/02/27 15:48
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -64,44 +64,44 @@ 64 64 65 65 Errors names and codes are in the table below. 66 66 67 -|**Error name**|**Errorcode**|**Description**68 -| Overcurrent|OC|Highcurrent69 -| Undervoltage|UV|Lowvoltage70 -| Overvoltage|OV|Highvoltage71 -| Low DCH temp.|LDT|Batterytemperatureis toolowfordischarging72 -| High DCH temp.|HDT|Batterytemperatureistoo highfordischarging73 -| Batterycover|BC|Battery coverisopened74 -| High humidity|HH|Highhumidity75 -| Water|WA|Waterinthebattery76 -| Logic hi.temp.|LHT|TemperatureofaBMSLogicboardistoo high77 -| Logic offline|LOF|Noconnectionwitha BMS Logic board78 -|Cr iticalerror|CER|Criticalerror79 -|C rown error|CRO|Crownforkliftrror80 -|C ellcount|CEL|Wrong number ofcells81 -| HYGoffline|HYG|Noconnectionwiththe HYG forklift82 -| Need ACK|ACK|Acknowledgeoferrorsis needed83 -| Combiliftoffl.|COM|Noconnection withtheCombilift forklift84 -| Shortcircuit|SHC|Shortcircuit85 -| Cont. hi. temp.|CHT|Highttemperatureofacontactor86 -|Lo giccount|LOG|Wrongnumber ofBMS Logicboards87 -| ADC error|ADC|Wrongvalues fromthe ADC88 -| Currentsensor|CSE|Currentsensorisshortedoropened89 -| CH cont.cycle|CCC|Chargecontactorswitchestoofrequency90 -| DCHcont. cycle|DCC|Dischargecontactorswitchestoo frequency91 -| Shuntoffline|SHO|Noconnectionwiththeshuntsensor92 -|S hunt error|SHE|Internalerror oftheshuntsensor93 -| Settings error|SET|Checksum of settingsis wrong94 -| WDT reset|WDT|WatchdogtimerresettheBMS95 -| No temp. sens.|NTS|Notemperature sensorsconnectedtoaBMS Logic96 -|Short edtemp.|TSS|A temperature sensorconnectedto a BMS Logics shorted97 -|S piritoffline|SPI|No connectionwiththeSpirittruck98 -| Low CHtemp.|LCT|Batterytemperatureis toolowforcharging99 -| High CH temp.|HCT|Battery temperatureistoohighfor charging100 -| Mounterror|MNT|SD cardisnotmounted101 -| FS error|FSE|FilesystemonanSDcardiscorrupted102 -|Unallowable CH| UCH|Charging the battery through the discharging circuit103 -| Stuck contactor|STC|Contactoris stuck104 -| CH cont. feed.|CCF|Wrongfeedback signalfromthecharging contactor105 -|D CHcont. feed.|DCF|Wrongfeedbacksignalfromthedischarging contactor67 +|**Error code**|**Error name**|**Description** 68 +|ACK|Need ACK|Acknowledge of errors is needed 69 +|ADC|ADC error|Wrong values from the ADC 70 +|BC|Battery cover|Battery cover is opened 71 +|CCC|CH cont. cycle|Charge contactor switches too frequency 72 +|CCF|CH cont. feed.|Wrong feedback signal from the charging contactor 73 +|CEL|Cell count|Wrong number of cells 74 +|CER|Critical error|Critical error 75 +|CHT|Cont. hi. temp.|Hight temperature of a contactor 76 +|COM|Combilift offl.|No connection with the Combilift forklift 77 +|CRO|Crown error|Crown forklift error 78 +|CSE|Current sensor|Current sensor is shorted or opened 79 +|DCC|DCH cont. cycle|Discharge contactor switches too frequency 80 +|DCF|DCH cont. feed.|Wrong feedback signal from the discharging contactor 81 +|FSE|FS error|Filesystem on an SD card is corrupted 82 +|HCT|High CH temp.|Battery temperature is too high for charging 83 +|HDT|High DCH temp.|Battery temperature is too high for discharging 84 +|HH|High humidity|High humidity 85 +|HYG|HYG offline|No connection with the HYG forklift 86 +|LCT|Low CH temp.|Battery temperature is too low for charging 87 +|LDT|Low DCH temp.|Battery temperature is too low for discharging 88 +|LHT|Logic hi. temp.|Temperature of a BMS Logic board is too high 89 +|LOF|Logic offline|No connection with a BMS Logic board 90 +|LOG|Logic count|Wrong number of BMS Logic boards 91 +|MNT|Mount error|SD card is not mounted 92 +|NTS|No temp. sens.|No temperature sensors connected to a BMS Logic 93 +|OC|Overcurrent|High current 94 +|OV|Overvoltage|High voltage 95 +|SET|Settings error|Checksum of settings is wrong 96 +|SHC|Short circuit|Short circuit 97 +|SHE|Shunt error|Internal error of the shunt sensor 98 +|SHO|Shunt offline|No connection with the shunt sensor 99 +|SPI|Spirit offline|No connection with the Spirit truck 100 +|STC|Stuck contactor|Contactor is stuck 101 +|TSS|Shorted temp.|A temperature sensor connected to a BMS Logic is shorted 102 +|UCH|Unallowable CH|Charging the battery through the discharging circuit 103 +|UV|Undervoltage|Low voltage 104 +|WA|Water|Water in the battery 105 +|WDT|WDT reset|Watchdog timer reset the BMS 106 106 107 107