Changes for page 4. Indication

Last modified by Admin on 2025/02/27 15:48

From version 2.1
edited by Admin
on 2024/12/13 15:23
Change comment: There is no comment for this version
To version 3.1
edited by Admin
on 2024/12/13 15:23
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -64,44 +64,44 @@
64 64  
65 65  Errors names and codes are in the table below.
66 66  
67 -|**Error name**|**Error code**|**Description**
68 -|Overcurrent|OC|High current
69 -|Undervoltage|UV|Low voltage
70 -|Overvoltage|OV|High voltage
71 -|Low DCH temp.|LDT|Battery temperature is too low for discharging
72 -|High DCH temp.|HDT|Battery temperature is too high for discharging
73 -|Battery cover|BC|Battery cover is opened
74 -|High humidity|HH|High humidity
75 -|Water|WA|Water in the battery
76 -|Logic hi. temp.|LHT|Temperature of a BMS Logic board is too high
77 -|Logic offline|LOF|No connection with a BMS Logic board
78 -|Critical error|CER|Critical error
79 -|Crown error|CRO|Crown forklift error
80 -|Cell count|CEL|Wrong number of cells
81 -|HYG offline|HYG|No connection with the HYG forklift
82 -|Need ACK|ACK|Acknowledge of errors is needed
83 -|Combilift offl.|COM|No connection with the Combilift forklift
84 -|Short circuit|SHC|Short circuit
85 -|Cont. hi. temp.|CHT|Hight temperature of a contactor
86 -|Logic count|LOG|Wrong number of BMS Logic boards
87 -|ADC error|ADC|Wrong values from the ADC
88 -|Current sensor|CSE|Current sensor is shorted or opened
89 -|CH cont. cycle|CCC|Charge contactor switches too frequency
90 -|DCH cont. cycle|DCC|Discharge contactor switches too frequency
91 -|Shunt offline|SHO|No connection with the shunt sensor
92 -|Shunt error|SHE|Internal error of the shunt sensor
93 -|Settings error|SET|Checksum of settings is wrong
94 -|WDT reset|WDT|Watchdog timer reset the BMS
95 -|No temp. sens.|NTS|No temperature sensors connected to a BMS Logic
96 -|Shorted temp.|TSS|A temperature sensor connected to a BMS Logic is shorted
97 -|Spirit offline|SPI|No connection with the Spirit truck
98 -|Low CH temp.|LCT|Battery temperature is too low for charging
99 -|High CH temp.|HCT|Battery temperature is too high for charging
100 -|Mount error|MNT|SD card is not mounted
101 -|FS error|FSE|Filesystem on an SD card is corrupted
102 -|Unallowable CH|UCH|Charging the battery through the discharging circuit
103 -|Stuck contactor|STC|Contactor is stuck
104 -|CH cont. feed.|CCF|Wrong feedback signal from the charging contactor
105 -|DCH cont. feed.|DCF|Wrong feedback signal from the discharging contactor
67 +|**Error code**|**Error name**|**Description**
68 +|OC|Overcurrent|High current
69 +|UV|Undervoltage|Low voltage
70 +|OV|Overvoltage|High voltage
71 +|LDT|Low DCH temp.|Battery temperature is too low for discharging
72 +|HDT|High DCH temp.|Battery temperature is too high for discharging
73 +|BC|Battery cover|Battery cover is opened
74 +|HH|High humidity|High humidity
75 +|WA|Water|Water in the battery
76 +|LHT|Logic hi. temp.|Temperature of a BMS Logic board is too high
77 +|LOF|Logic offline|No connection with a BMS Logic board
78 +|CER|Critical error|Critical error
79 +|CRO|Crown error|Crown forklift error
80 +|CEL|Cell count|Wrong number of cells
81 +|HYG|HYG offline|No connection with the HYG forklift
82 +|ACK|Need ACK|Acknowledge of errors is needed
83 +|COM|Combilift offl.|No connection with the Combilift forklift
84 +|SHC|Short circuit|Short circuit
85 +|CHT|Cont. hi. temp.|Hight temperature of a contactor
86 +|LOG|Logic count|Wrong number of BMS Logic boards
87 +|ADC|ADC error|Wrong values from the ADC
88 +|CSE|Current sensor|Current sensor is shorted or opened
89 +|CCC|CH cont. cycle|Charge contactor switches too frequency
90 +|DCC|DCH cont. cycle|Discharge contactor switches too frequency
91 +|SHO|Shunt offline|No connection with the shunt sensor
92 +|SHE|Shunt error|Internal error of the shunt sensor
93 +|SET|Settings error|Checksum of settings is wrong
94 +|WDT|WDT reset|Watchdog timer reset the BMS
95 +|NTS|No temp. sens.|No temperature sensors connected to a BMS Logic
96 +|TSS|Shorted temp.|A temperature sensor connected to a BMS Logic is shorted
97 +|SPI|Spirit offline|No connection with the Spirit truck
98 +|LCT|Low CH temp.|Battery temperature is too low for charging
99 +|HCT|High CH temp.|Battery temperature is too high for charging
100 +|MNT|Mount error|SD card is not mounted
101 +|FSE|FS error|Filesystem on an SD card is corrupted
102 +|UCH|Unallowable CH|Charging the battery through the discharging circuit
103 +|STC|Stuck contactor|Contactor is stuck
104 +|CCF|CH cont. feed.|Wrong feedback signal from the charging contactor
105 +|DCF|DCH cont. feed.|Wrong feedback signal from the discharging contactor
106 106  
107 107