Changes for page 3. Configuration

Last modified by Admin on 2025/02/27 16:44

From version 4.11
edited by Admin
on 2025/02/27 15:16
Change comment: There is no comment for this version
To version 5.1
edited by Admin
on 2025/02/27 15:18
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,7 +1,7 @@
1 1  (% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 2  = Configuration =
3 3  
4 -The BMS Display 1.x is configured over the CAN bus (P3, P4 or P5 headers can be used). The device is a slave in the CANopen network.
4 +The BMS Display is configured over the CAN bus (P3, P4 or P5 headers can be used). The device is a slave in the CANopen network.
5 5  
6 6  The default settings to connect to the BMS Display 1.x are:
7 7  
... ... @@ -8,7 +8,7 @@
8 8  * CAN bus rate, kbps — 250;
9 9  * CANopen Node ID — 20.
10 10  
11 -To change the BMS Display 1.x parameters use the ElectricDeviceMonitor software.
11 +To change the BMS Display parameters use the ElectricDeviceMonitor software.
12 12  
13 13  [[image:1734102385594-603.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="336" width="300"]]
14 14  
... ... @@ -16,7 +16,7 @@
16 16  
17 17  [[image:1740668861900-680.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="238" width="450"]]
18 18  
19 -Connection to the BMS Display 1.x can be done using the following USB-CAN adapters:
19 +Connection to the BMS Display can be done using the following USB-CAN adapters:
20 20  
21 21  * Systec USB-CANmodul1
22 22  * PEAK PCAN-USB
... ... @@ -48,7 +48,7 @@
48 48  
49 49  * CANopen Node ID – an identifier of the device in the CANopen network (20 by default);
50 50  * CAN baud rate – CAN bus speed, kbps;
51 -* Device type
51 +* Device type – a type of controller connected. Since firmware v1.5.0 BMS Display automatically detects device type;
52 52  * BMS Main Node ID – an identifier of the BMS controller in the CANopen network (32 by default);
53 53  * Heartbeat – a flag for sending Heartbeat messages;