2 | = Installation and connection = | ||
3 | |||
![]() |
8.2 | 4 | == Safety rules == |
5 | |||
6 | (% class="wikigeneratedid" %) | ||
![]() |
9.1 | 7 | Before use, **configure the system**. Proper operation of the device is possible only if it is correctly configured. |
![]() |
8.2 | 8 | |
9 | (% class="box warningmessage" %) | ||
10 | ((( | ||
11 | To prevent the damage of device avoid electrostatic discharges while working with the battery. | ||
12 | ))) | ||
13 | |||
![]() |
1.1 | 14 | == Installation == |
15 | |||
16 | [[image:1734102043915-364.png||data-xwiki-image-style-alignment="center" height="355" width="600"]] | ||
17 | |||
18 | |**Parameter**|**Value** | ||
19 | |Overall dimensions (length × width × height), mm|140 × 37 × 23 | ||
20 | |Mounting dimensions (length × width), mm|134 × 31 | ||
21 | |Mounting holes|M3 | ||
22 | |||
![]() |
5.1 | 23 | == Headers == |
![]() |
1.1 | 24 | |
25 | The BMS Display has three headers for connecting the BMS (P3, P4 и P5), a header for an external button (P6) and a switch which connects a terminal resistor to the CAN bus (SWD1). | ||
26 | |||
27 | === P3, P4 and P5 – headers for communication with BMS === | ||
28 | |||
![]() |
8.1 | 29 | Receptacle Housing: Molex 430250400. Terminals: Molex 43030 |
![]() |
5.3 | 30 | |
![]() |
1.1 | 31 | [[image:1734102177551-232.png||data-xwiki-image-style-alignment="center" height="77" width="73"]] |
32 | |||
33 | |**Pin**|**Name**|**Description** | ||
34 | |**1**|**CANH**|CAN H line for communication with the BMS controller | ||
35 | |**2**|**CANL**|CAN L line for communication with the BMS controller | ||
![]() |
6.1 | 36 | |**3**|**+5V**|Supply voltage 5V |
![]() |
1.1 | 37 | |**4**|**GND**|Ground |
38 | |||
![]() |
4.1 | 39 | === P6 – header for external button === |
![]() |
1.1 | 40 | |
![]() |
8.1 | 41 | Receptacle Housing: Molex 430250200. Terminals: Molex 43030 |
![]() |
5.3 | 42 | |
![]() |
4.1 | 43 | [[image:1734102225110-114.png||data-xwiki-image-style-alignment="center" height="79" width="44"]] |
44 | |||
![]() |
1.1 | 45 | |**Pin**|**Name**|**Description** |
46 | |**1**|**BTN1**|Button line (dry contact) | ||
47 | |**2**|**BTN2**|Button line (dry contact) | ||
48 | |||
49 | === SWD1 - CAN terminal resistor switch === | ||
50 | |||
51 | To connect the terminal resistor between the **CANH** and **CANL** lines, switch the SWD1 to the ON position. |