Wiki source code of 2. Installation and connection

Version 5.2 by Admin on 2024/12/13 16:00

Hide last authors
Admin 1.1 1 (% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 = Installation and connection =
3
4 == Installation ==
5
6 [[image:1734102043915-364.png||data-xwiki-image-style-alignment="center" height="355" width="600"]]
7
8 |**Parameter**|**Value**
9 |Overall dimensions (length × width × height), mm|140 × 37 × 23
10 |Mounting dimensions (length × width), mm|134 × 31
11 |Mounting holes|M3
12 |Header types|Molex series Micro-Fit
13
Admin 5.1 14 == Headers ==
Admin 1.1 15
16 The BMS Display has three headers for connecting the BMS (P3, P4 и P5), a header for an external button (P6) and a switch which connects a terminal resistor to the CAN bus (SWD1).
17
18 === P3, P4 and P5 – headers for communication with BMS ===
19
20 [[image:1734102177551-232.png||data-xwiki-image-style-alignment="center" height="77" width="73"]]
21
22 |**Pin**|**Name**|**Description**
23 |**1**|**CANH**|CAN H line for communication with the BMS controller
24 |**2**|**CANL**|CAN L line for communication with the BMS controller
25 |**3**|**+5V**|Supply voltage 5 V
26 |**4**|**GND**|Ground
27
Admin 4.1 28 === P6 – header for external button ===
Admin 1.1 29
Admin 4.1 30 [[image:1734102225110-114.png||data-xwiki-image-style-alignment="center" height="79" width="44"]]
31
Admin 1.1 32 |**Pin**|**Name**|**Description**
33 |**1**|**BTN1**|Button line (dry contact)
34 |**2**|**BTN2**|Button line (dry contact)
35
36 === SWD1 - CAN terminal resistor switch ===
37
38 To connect the terminal resistor between the **CANH** and **CANL** lines, switch the SWD1 to the ON position.