Changes for page 2. Strings controllers: signals and errors
Last modified by Admin on 2025/02/21 14:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -11,27 +11,27 @@ 11 11 (% style="width:1274px" %) 12 12 |=(% colspan="1" rowspan="2" style="width: 198px;" %)**Name**|=(% rowspan="2" style="width: 60px;" %)**Abbr.**|=(% colspan="1" rowspan="2" style="width: 483px;" %)**Description**|=(% colspan="3" rowspan="1" style="width: 248px;" %)**Compability**|=(% colspan="1" rowspan="2" style="width: 143px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 140px;" %)**Modbus** 13 13 |=(% style="width: 98px;" %)**Mini S / Mini**|=(% style="width: 77px;" %)**Main 2.1**|=(% style="width: 81px;" %)**Main 3** 14 -| Balancingrequest|BR|arequestobalancethe cells;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %)15 -| Batterycover|CVR|a signalfromthe batterycover;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %)16 -| CHcontactorfeedback|CCF|asignalfromchargingcontactorfeedbackloop;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %)17 -| CH/DCHcontactorfeedback|CDF|asignalfromcharging/discharging contactorfeedback loop;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %)18 -| Chargerequest|CRE|arequest toclose the charging contactor;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %)19 -| Chargerconnected |CON|asignalndicatingthatchargerisconnected;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %)20 -| Circuitbreakerstatus|CBS|statusofprotectiondisconnector;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %)21 -| CloseExternal1 |CE1|arequesttoclosee External1discreteoutput(ifassigned).|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %)22 -| CloseMain contactor |CMC|a request to close themain contactor;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %)23 -| DCHcontactorfeedback|DCF|asignalfromdischarging contactorfeedback loop;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %)24 -| Dischargerequest|DRE|arequestocloseedischarging contactor;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %)25 -| Fuse1|signal fromfuse1;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %)26 -| Fuse2|F2|signal from fuse2;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %)27 -| Fuse3|F3|signal fromfuse3;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %)28 -| Inhibitcharging|ICH|acommando openthechargingcontactor;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %)29 -| Inhibitdischarging|IDC|acommando openthedischargingcontactor;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %)30 -| Insulationstatus|INS|asignal fromaninsulation monitoringdevice;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %)31 -| Interlock | |asignalfrominterlock loop;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %)32 -| Maincontactorfeedback|MCF|asignalfrommain contactorfeedbackloop;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %)33 -| PCHcontactorfeedback|PCF|asignalfromprechargingcontactorfeedback loop;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %)34 -| Powerup/downrequest |PDN|arequest topowerdownthedevice;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %)14 +|(% style="width:198px" %)Battery cover |(% style="width:60px" %)CVR|(% style="width:483px" %)a signal from the battery cover;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 15 +|(% style="width:198px" %)Charger connected |(% style="width:60px" %)CON|(% style="width:483px" %)a signal indicating that charger is connected;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 16 +|(% style="width:198px" %)Power up/down request |(% style="width:60px" %)PDN|(% style="width:483px" %)a request to power down the device;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 17 +|(% style="width:198px" %)Inhibit charging |(% style="width:60px" %)ICH|(% style="width:483px" %)a command to open the charging contactor;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 18 +|(% style="width:198px" %)Inhibit discharging |(% style="width:60px" %)IDC|(% style="width:483px" %)a command to open the discharging contactor;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 19 +|(% style="width:198px" %)CH contactor feedback |(% style="width:60px" %)CCF|(% style="width:483px" %)a signal from charging contactor feedback loop;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 20 +|(% style="width:198px" %)DCH contactor feedback |(% style="width:60px" %)DCF|(% style="width:483px" %)a signal from discharging contactor feedback loop;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 21 +|(% style="width:198px" %)Insulation status |(% style="width:60px" %)INS|(% style="width:483px" %)a signal from an insulation monitoring device;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 22 +|(% style="width:198px" %)Charge request |(% style="width:60px" %)CRE|(% style="width:483px" %)a request to close the charging contactor;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 23 +|(% style="width:198px" %)Discharge request |(% style="width:60px" %)DRE|(% style="width:483px" %)a request to close the discharging contactor;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 24 +|(% style="width:198px" %)PCH contactor feedback |(% style="width:60px" %)PCF|(% style="width:483px" %)a signal from precharging contactor feedback loop;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 25 +|(% style="width:198px" %)CH/DCH contactor feedback |(% style="width:60px" %)CDF|(% style="width:483px" %)a signal from charging/discharging contactor feedback loop;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 26 +|(% style="width:198px" %)Main contactor feedback |(% style="width:60px" %)MCF|(% style="width:483px" %)a signal from main contactor feedback loop;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 27 +|(% style="width:198px" %)Interlock |(% style="width:60px" %) |(% style="width:483px" %)a signal from interlock loop;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 28 +|(% style="width:198px" %)Fuse 1|(% style="width:60px" %)F1|(% style="width:483px" %)signal from fuse 1;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 29 +|(% style="width:198px" %)Fuse 2|(% style="width:60px" %)F2|(% style="width:483px" %)signal from fuse 2;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 30 +|(% style="width:198px" %)Fuse 3 |(% style="width:60px" %)F3|(% style="width:483px" %)signal from fuse 3;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 31 +|(% style="width:198px" %)Circuit breaker status |(% style="width:60px" %)CBS|(% style="width:483px" %)status of protection disconnector;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 32 +|(% style="width:198px" %)Balancing request |(% style="width:60px" %)BR|(% style="width:483px" %)a request to balance the cells;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 33 +|(% style="width:198px" %)Close Main contactor |(% style="width:60px" %)CMC|(% style="width:483px" %)a request to close the main contactor;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 34 +|(% style="width:198px" %)Close External 1 |(% style="width:60px" %)CE1|(% style="width:483px" %)a request to close the External 1 discrete output (if assigned).|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 35 35 36 36 === List of internal states === 37 37