Last modified by Admin on 2025/02/21 14:51

From version 9.60
edited by Admin
on 2025/01/30 15:26
Change comment: There is no comment for this version
To version 9.62
edited by Admin
on 2025/01/30 15:28
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -44,36 +44,40 @@
44 44  (% style="width:1277px" %)
45 45  |=(% colspan="1" rowspan="2" style="width: 201px;" %)**Name**|=(% rowspan="2" style="width: 55px;" %)**Abbr.**|=(% colspan="1" rowspan="2" style="width: 531px;" %)**Description**|=(% colspan="3" rowspan="1" style="width: 255px;" %)**Compability**|=(% colspan="1" rowspan="2" style="width: 140px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 142px;" %)**Modbus**
46 46  |=(% style="width: 94px;" %)**Mini S / Mini**|=(% style="width: 75px;" %)**Main 2.1**|=(% style="width: 84px;" %)**Main 3**
47 -|Allow charging |ACH|a signal for a charger to start charging;|**Yes**|**Yes**|**Yes**|(% style="width:140px" %) |(% style="width:142px" %)
48 -|Balancing 1 |BA1|balancing the first series of cells;| |**Yes**|**Yes**|(% style="width:140px" %) |(% style="width:142px" %)
49 -|Balancing 2 |BA2|balancing the second series of cells;| |**Yes**|**Yes**|(% style="width:140px" %) |(% style="width:142px" %)
50 -|Cell analysis|CEA| |//Yes~*~**//|//Yes~*~**//|//Yes~*~**//|(% style="width:140px" %) |(% style="width:142px" %)
51 -|Charging current present |CCP|the presence of the charging current;|**Yes**|**Yes**|**Yes**|(% style="width:140px" %) |(% style="width:142px" %)
52 -|Charging |CH|state of the charging contactor;|**Yes**|**Yes**|**Yes**|(% style="width:140px" %) |(% style="width:142px" %)
53 -|Charging/discharging|C/D|state of the charging/discharging contactor;|**Yes**|**Yes**|**Yes**|(% style="width:140px" %) |(% style="width:142px" %)
54 -|Cooler |COO|a command to turn on a cooler;|**Yes**|**Yes**|**Yes**|(% style="width:140px" %) |(% style="width:142px" %)
55 -|Crown EWS|EWS| |//Yes~*~**//|//Yes~*~**//|//Yes~*~**//|(% style="width:140px" %) |(% style="width:142px" %)
56 -|Discharging (AUX) |AUX|state of the auxiliary discharging contactor;|**Yes**|**Yes**|**Yes**|(% style="width:140px" %) |(% style="width:142px" %)
57 -|Discharging current present |DCP|the presence of the discharging current;|**Yes**|**Yes**|**Yes**|(% style="width:140px" %) |(% style="width:142px" %)
58 -|Discharging |DCH|state of the discharging contactor;|**Yes**|**Yes**|**Yes**|(% style="width:140px" %) |(% style="width:142px" %)
59 -|External 1 |EX1|a signal that activates by the remote request.|**Yes**|**Yes**|**Yes**|(% style="width:140px" %) |(% style="width:142px" %)
60 -|Heater (AUX)|HA| | |**Yes**|**Yes**|(% style="width:140px" %) |(% style="width:142px" %)
61 -|Heater |HEA|a command to turn on a heater;|**Yes**|**Yes**|**Yes**|(% style="width:140px" %) |(% style="width:142px" %)
62 -|High charging current |HCC|charging current is high;|**Yes**|**Yes**|**Yes**|(% style="width:140px" %) |(% style="width:142px" %)
63 -|Init|INI| |//Yes~*~**//|//Yes~*~**//|//Yes~*~**//|(% style="width:140px" %) |(% style="width:142px" %)
64 -|Low SOC |LOS|a signal corresponding the low SOC of the battery;|**Yes**|**Yes**|**Yes**|(% style="width:140px" %) |(% style="width:142px" %)
65 -|Main contactor |MCO|state of the main contactor;|**Yes**|**Yes**|**Yes**|(% style="width:140px" %) |(% style="width:142px" %)
66 -|Power down ACK |PDA|an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request;|**Yes**|**Yes**|**Yes**|(% style="width:140px" %) |(% style="width:142px" %)
67 -|Power up |PUP|an indication of BMS power status;|**Yes**|**Yes**|**Yes**|(% style="width:140px" %) |(% style="width:142px" %)
68 -|Precharging |PRE|state of the precharging contactor;|**Yes**|**Yes**|**Yes**|(% style="width:140px" %) |(% style="width:142px" %)
69 -|Ready to charge |RTC|the battery is ready to be charged;|**Yes**|**Yes**|**Yes**|(% style="width:140px" %) |(% style="width:142px" %)
70 -|Ready to discharge |RTD|the battery is ready to be discharged;|**Yes**|**Yes**|**Yes**|(% style="width:140px" %) |(% style="width:142px" %)
71 -|Service reset|SR| |//Yes~*~**//| |//Yes~*~**//|(% style="width:140px" %) |(% style="width:142px" %)
72 -|Shutdown request (Combilift)|CSH| |//Yes~*~**//|//Yes~*~**//|//Yes~*~**//|(% style="width:140px" %) |(% style="width:142px" %)
73 -|Shutdown request (HYG/Spirit)|HSH| |//Yes~*~**//|//Yes~*~**//|//Yes~*~**//|(% style="width:140px" %) |(% style="width:142px" %)
74 -|Voltage too high for charging|ENV| |//Yes~*~**//|//Yes~*~**//|//Yes~*~**//|(% style="width:140px" %) |(% style="width:142px" %)
47 +|Allow charging |ACH|a signal for a charger to start charging;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
48 +|Balancing 1 |BA1|balancing the first series of cells;| |Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
49 +|Balancing 2 |BA2|balancing the second series of cells;| |Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
50 +|Cell analysis|CEA| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |(% style="width:142px" %)
51 +|Charging current present |CCP|the presence of the charging current;|Yes|Yes~*~*|Yes|(% style="width:140px" %) |(% style="width:142px" %)
52 +|Charging |CH|state of the charging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
53 +|Charging/discharging|C/D|state of the charging/discharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
54 +|Cooler |COO|a command to turn on a cooler;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
55 +|Crown EWS|EWS| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |(% style="width:142px" %)
56 +|Discharging (AUX) |AUX|state of the auxiliary discharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
57 +|Discharging current present |DCP|the presence of the discharging current;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
58 +|Discharging |DCH|state of the discharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
59 +|External 1 |EX1|a signal that activates by the remote request.|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
60 +|Heater (AUX)|HA| | |Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
61 +|Heater |HEA|a command to turn on a heater;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
62 +|High charging current |HCC|charging current is high;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
63 +|Init|INI| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |(% style="width:142px" %)
64 +|Low SOC |LOS|a signal corresponding the low SOC of the battery;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
65 +|Main contactor |MCO|state of the main contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
66 +|Power down ACK |PDA|an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
67 +|Power up |PUP|an indication of BMS power status;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
68 +|Precharging |PRE|state of the precharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
69 +|Ready to charge |RTC|the battery is ready to be charged;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
70 +|Ready to discharge |RTD|the battery is ready to be discharged;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
71 +|Service reset|SR| |Yes~*~**| |Yes~*~**|(% style="width:140px" %) |(% style="width:142px" %)
72 +|Shutdown request (Combilift)|CSH| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |(% style="width:142px" %)
73 +|Shutdown request (HYG/Spirit)|HSH| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |(% style="width:142px" %)
74 +|Voltage too high for charging|ENV| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |(% style="width:142px" %)
75 75  
76 76  
77 +
78 +(% class="wikigeneratedid" %)
79 +~*~*~* those states are indicative only and cannot be assigned to discrete output or relay.
80 +
77 77  === List of errors ===
78 78  
79 79  (% style="width:1279px" %)