Changes for page 2. Strings controllers: signals and errors
Last modified by Admin on 2025/02/21 14:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -47,31 +47,31 @@ 47 47 |Allow charging |ACH|a signal for a charger to start charging;|**Yes**|**Yes**|**Yes**|(% style="width:140px" %) |(% style="width:142px" %) 48 48 |Balancing 1 |BA1|balancing the first series of cells;| |**Yes**|**Yes**|(% style="width:140px" %) |(% style="width:142px" %) 49 49 |Balancing 2 |BA2|balancing the second series of cells;| |**Yes**|**Yes**|(% style="width:140px" %) |(% style="width:142px" %) 50 -|Cell analysis|CEA| | //Yes~*~**//|//Yes~*~**//|//Yes~*~**//|(% style="width:140px" %) |(% style="width:142px" %)50 +|Cell analysis|CEA| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 51 51 |Charging current present |CCP|the presence of the charging current;|**Yes**|**Yes**|**Yes**|(% style="width:140px" %) |(% style="width:142px" %) 52 52 |Charging |CH|state of the charging contactor;|**Yes**|**Yes**|**Yes**|(% style="width:140px" %) |(% style="width:142px" %) 53 53 |Charging/discharging|C/D|state of the charging/discharging contactor;|**Yes**|**Yes**|**Yes**|(% style="width:140px" %) |(% style="width:142px" %) 54 54 |Cooler |COO|a command to turn on a cooler;|**Yes**|**Yes**|**Yes**|(% style="width:140px" %) |(% style="width:142px" %) 55 -|Crown EWS|EWS| | //Yes~*~**//|//Yes~*~**//|//Yes~*~**//|(% style="width:140px" %) |(% style="width:142px" %)56 -|Discharging (AUX) |AUX|state of the auxiliary discharging contactor;| **Yes**|**Yes**|**Yes**|(% style="width:140px" %) |(% style="width:142px" %)57 -|Discharging current present |DCP|the presence of the discharging current;| **Yes**|**Yes**|**Yes**|(% style="width:140px" %) |(% style="width:142px" %)58 -|Discharging |DCH|state of the discharging contactor;| **Yes**|**Yes**|**Yes**|(% style="width:140px" %) |(% style="width:142px" %)59 -|External 1 |EX1|a signal that activates by the remote request.| **Yes**|**Yes**|**Yes**|(% style="width:140px" %) |(% style="width:142px" %)60 -|Heater (AUX)|HA| | | **Yes**|**Yes**|(% style="width:140px" %) |(% style="width:142px" %)61 -|Heater |HEA|a command to turn on a heater;| **Yes**|**Yes**|**Yes**|(% style="width:140px" %) |(% style="width:142px" %)62 -|High charging current |HCC|charging current is high;| **Yes**|**Yes**|**Yes**|(% style="width:140px" %) |(% style="width:142px" %)63 -|Init|INI| | //Yes~*~**//|//Yes~*~**//|//Yes~*~**//|(% style="width:140px" %) |(% style="width:142px" %)64 -|Low SOC |LOS|a signal corresponding the low SOC of the battery;| **Yes**|**Yes**|**Yes**|(% style="width:140px" %) |(% style="width:142px" %)65 -|Main contactor |MCO|state of the main contactor;| **Yes**|**Yes**|**Yes**|(% style="width:140px" %) |(% style="width:142px" %)66 -|Power down ACK |PDA|an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request;| **Yes**|**Yes**|**Yes**|(% style="width:140px" %) |(% style="width:142px" %)67 -|Power up |PUP|an indication of BMS power status;| **Yes**|**Yes**|**Yes**|(% style="width:140px" %) |(% style="width:142px" %)68 -|Precharging |PRE|state of the precharging contactor;| **Yes**|**Yes**|**Yes**|(% style="width:140px" %) |(% style="width:142px" %)69 -|Ready to charge |RTC|the battery is ready to be charged;| **Yes**|**Yes**|**Yes**|(% style="width:140px" %) |(% style="width:142px" %)70 -|Ready to discharge |RTD|the battery is ready to be discharged;| **Yes**|**Yes**|**Yes**|(% style="width:140px" %) |(% style="width:142px" %)71 -|Service reset|SR| | //Yes~*~**//| |//Yes//|(% style="width:140px" %) |(% style="width:142px" %)72 -|Shutdown request (Combilift)|CSH| | //Yes//|//Yes//|//Yes//|(% style="width:140px" %) |(% style="width:142px" %)73 -|Shutdown request (HYG/Spirit)|HSH| | //Yes//|//Yes//|//Yes//|(% style="width:140px" %) |(% style="width:142px" %)74 -|Voltage too high for charging|ENV| | //Yes//|//Yes//|//Yes//|(% style="width:140px" %) |(% style="width:142px" %)55 +|Crown EWS|EWS| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 56 +|Discharging (AUX) |AUX|state of the auxiliary discharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 57 +|Discharging current present |DCP|the presence of the discharging current;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 58 +|Discharging |DCH|state of the discharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 59 +|External 1 |EX1|a signal that activates by the remote request.|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 60 +|Heater (AUX)|HA| | |Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 61 +|Heater |HEA|a command to turn on a heater;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 62 +|High charging current |HCC|charging current is high;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 63 +|Init|INI| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 64 +|Low SOC |LOS|a signal corresponding the low SOC of the battery;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 65 +|Main contactor |MCO|state of the main contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 66 +|Power down ACK |PDA|an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 67 +|Power up |PUP|an indication of BMS power status;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 68 +|Precharging |PRE|state of the precharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 69 +|Ready to charge |RTC|the battery is ready to be charged;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 70 +|Ready to discharge |RTD|the battery is ready to be discharged;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 71 +|Service reset|SR| |Yes| |Yes|(% style="width:140px" %) |(% style="width:142px" %) 72 +|Shutdown request (Combilift)|CSH| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 73 +|Shutdown request (HYG/Spirit)|HSH| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 74 +|Voltage too high for charging|ENV| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 75 75 76 76 77 77 === List of errors ===