Changes for page 2. Strings controllers: signals and errors
Last modified by Admin on 2025/02/21 14:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -44,36 +44,44 @@ 44 44 (% style="width:1277px" %) 45 45 |=(% colspan="1" rowspan="2" style="width: 201px;" %)**Name**|=(% rowspan="2" style="width: 55px;" %)**Abbr.**|=(% colspan="1" rowspan="2" style="width: 531px;" %)**Description**|=(% colspan="3" rowspan="1" style="width: 255px;" %)**Compability**|=(% colspan="1" rowspan="2" style="width: 140px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 142px;" %)**Modbus** 46 46 |=(% style="width: 94px;" %)**Mini S / Mini**|=(% style="width: 75px;" %)**Main 2.1**|=(% style="width: 84px;" %)**Main 3** 47 -|Allow charging |ACH|a signal for a charger to start charging;| **Yes**|**Yes**|**Yes**|(% style="width:140px" %) |(% style="width:142px" %)48 -|Balancing 1 |BA1|balancing the first series of cells;| | **Yes**|**Yes**|(% style="width:140px" %) |(% style="width:142px" %)49 -|Balancing 2 |BA2|balancing the second series of cells;| | **Yes**|**Yes**|(% style="width:140px" %) |(% style="width:142px" %)50 -|Cell analysis|CEA| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 51 -|Charging current present |CCP|the presence of the charging current;| **Yes**|**Yes**|**Yes**|(% style="width:140px" %) |(% style="width:142px" %)52 -|Charging |CH|state of the charging contactor;| **Yes**|**Yes**|**Yes**|(% style="width:140px" %) |(% style="width:142px" %)53 -|Charging/discharging|C/D|state of the charging/discharging contactor;| **Yes**|**Yes**|**Yes**|(% style="width:140px" %) |(% style="width:142px" %)54 -|Cooler |COO|a command to turn on a cooler;| **Yes**|**Yes**|**Yes**|(% style="width:140px" %) |(% style="width:142px" %)55 -|Crown EWS|EWS| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 47 +|Allow charging |ACH|a signal for a charger to start charging;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 48 +|Balancing 1 |BA1|balancing the first series of cells;| |Yes*|Yes|(% style="width:140px" %) |(% style="width:142px" %) 49 +|Balancing 2 |BA2|balancing the second series of cells;| |Yes*|Yes|(% style="width:140px" %) |(% style="width:142px" %) 50 +|Cell analysis|CEA| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |(% style="width:142px" %) 51 +|Charging current present |CCP|the presence of the charging current;|Yes|Yes~*~*|Yes|(% style="width:140px" %) |(% style="width:142px" %) 52 +|Charging |CH|state of the charging contactor;|Yes|Yes*|Yes|(% style="width:140px" %) |(% style="width:142px" %) 53 +|Charging/discharging|C/D|state of the charging/discharging contactor;|Yes|Yes*|Yes|(% style="width:140px" %) |(% style="width:142px" %) 54 +|Cooler |COO|a command to turn on a cooler;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 55 +|Crown EWS|EWS| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |(% style="width:142px" %) 56 56 |Discharging (AUX) |AUX|state of the auxiliary discharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 57 -|Discharging current present |DCP|the presence of the discharging current;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 58 -|Discharging |DCH|state of the discharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 57 +|Discharging current present |DCP|the presence of the discharging current;|Yes|Yes~*~*|Yes|(% style="width:140px" %) |(% style="width:142px" %) 58 +|Discharging |DCH|state of the discharging contactor;|Yes|Yes*|Yes|(% style="width:140px" %) |(% style="width:142px" %) 59 59 |External 1 |EX1|a signal that activates by the remote request.|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 60 60 |Heater (AUX)|HA| | |Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 61 61 |Heater |HEA|a command to turn on a heater;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 62 -|High charging current |HCC|charging current is high;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 63 -|Init|INI| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 62 +|High charging current |HCC|charging current is high;|Yes|Yes~*~*|Yes|(% style="width:140px" %) |(% style="width:142px" %) 63 +|Init|INI| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |(% style="width:142px" %) 64 64 |Low SOC |LOS|a signal corresponding the low SOC of the battery;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 65 -|Main contactor |MCO|state of the main contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 66 -|Power down ACK |PDA|an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 65 +|Main contactor |MCO|state of the main contactor;|Yes|Yes*|Yes|(% style="width:140px" %) |(% style="width:142px" %) 66 +|Power down ACK |PDA|an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request;|Yes|Yes~*~*|Yes|(% style="width:140px" %) |(% style="width:142px" %) 67 67 |Power up |PUP|an indication of BMS power status;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 68 68 |Precharging |PRE|state of the precharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 69 69 |Ready to charge |RTC|the battery is ready to be charged;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 70 70 |Ready to discharge |RTD|the battery is ready to be discharged;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 71 -|Service reset|SR| |Yes| |Yes|(% style="width:140px" %) |(% style="width:142px" %) 72 -|Shutdown request (Combilift)|CSH| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 73 -|Shutdown request (HYG/Spirit)|HSH| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 74 -|Voltage too high for charging|ENV| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 71 +|Service reset|SR| |Yes~*~**| |Yes~*~**|(% style="width:140px" %) |(% style="width:142px" %) 72 +|Shutdown request (Combilift)|CSH| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |(% style="width:142px" %) 73 +|Shutdown request (HYG/Spirit)|HSH| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |(% style="width:142px" %) 74 +|Voltage too high for charging|ENV| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |(% style="width:142px" %) 75 75 76 +(% class="wikigeneratedid" %) 77 +~* assignable to relay only 76 76 79 +(% class="wikigeneratedid" %) 80 +~** assignable to discrete input only 81 + 82 +(% class="wikigeneratedid" %) 83 +~*~*~* state is indicative only and cannot be assigned to discrete output or relay. 84 + 77 77 === List of errors === 78 78 79 79 (% style="width:1279px" %) ... ... @@ -94,9 +94,9 @@ 94 94 |DCH contactor cycles error |DCC|switching frequency of the discharging contactor is too high;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 95 95 |DCH contactor feedback error |DCF|the control signals for the discharging contactor and the contactor feedback differ;|•| |Yes| |(% style="width:142px" %) |(% style="width:134px" %) 96 96 |FS error|FSE| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 97 -|General error|GE| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 105 +|General error|GE| | |Yes*|Yes*|Yes|(% style="width:142px" %) |(% style="width:134px" %) 98 98 |High contactor temperature|CHT| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 99 -|High humidity |HH|humidity of the battery is increased;| | Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)107 +|High humidity |HH|humidity of the battery is increased;| | |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 100 100 |High Logic temperature |LHT|at least one of the Logic devices is overheated;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 101 101 |High temperature (CH) |HCT|temperature is too high for charging;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 102 102 |High temperature (DCH) |HDT|temperature is too high for discharging;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) ... ... @@ -127,7 +127,7 @@ 127 127 |Temperature sensor is shorted |TSS|some temperature sensors are shorted;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 128 128 |Unallowable charging |UCH|charging the battery through the discharging contactor;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 129 129 |Undervoltage|UV| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 130 -|Water |WA|there is water in the battery enclosure;|•| Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)138 +|Water |WA|there is water in the battery enclosure;|•| |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 131 131 |WDT reset |WDT|watchdog timer reset the device;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 132 132 133 - 141 +~* signal can be assigned to a discrete output and relay.